4.5.3
Ground connections
DANGER!
Risk of electric shock!
Any electrical equipment on the vehicle must be at a common potential (e.g. the vehicle frame). All
ground connections must therefore be connected.
→
Make sure that the heat sink is also grounded in a corresponding manner.
→
Do not rely on the connecting cables alone, as the pickup will not be de-energized and without voltage
even without connecting cables, as long as the primary side of the IP
®
system is active.
4.5.4
ESD protection
DANGER!
Risk of electric shock!
Because IPT
®
is an isolated system, depending on the vehicle design, ambient conditions, etc., charges
can build up on the vehicle and be stored there.
→
Make sure to provide an appropriate solution to dissipate this energy above ground on the system side
(e.g. conductive floor coating and discharge brushes, conductive rollers or similar) to avoid building up
such energy in order to ensure protection against the effects of electrostatic discharge.