Operating Instructions
750 W 27 V pickup
CQF 04/2 + Interface M12
BAL9100-0145a-EN
www.conductix.com
translated document
Page 22 of 40
7.4.3
Example: Interface not used
Below is an example of the connection of a device 91212-332-3108051 without using the interface.
Even if the signals of the
interface are not used, it is necessary to bridge contacts 1 and 4 in order to operate the device (e.g. with “Enable plug set”
91000-400-3089971).
The pilot contacts are not intended to serve as on/off switches. It is therefore not recommended to interrupt pilot connection under
load. The purpose of the switch shown below between the contacts 11 and 12 is resetting in case of error or in the protective state.
Further information can be found in chapter 10. The voltage on the pilot contacts is not isolated from the power output, so it must be
ensured that the switch used is sufficiently insulated against ground. 24V DC/0.1A is to be dimensioned between the contacts.
For details on the relay status during startup please refer to chapter 10.