Operating Instructions
750 W 27 V pickup
CQF 04/2 + Interface M12
BAL9100-0145a-EN
www.conductix.com
translated document
Page 21 of 40
7.4.2
Example: Use of the interface (recommended!)
The following is an example of the connection of the device 91212-332-3108051, if both the power output and the interface are
connected (recommended!).
The interface makes it possible to power up and shut down the device under load. It also allows a simple reset of the device in the
event of a detected error or protection condition. The basic reset function is achieved by a switch between contacts 1 and 4 on the
vehicle side. Due to the low voltage and the isolated design of the interface, a small sized switch can be used (24 V DC / 0.1 A).
For details on the relay status during startup please refer to chapter 10.