Operating Instructions
750 W 27 V pickup
CQF 04/2 + Interface M12
BAL9100-0145a-EN
www.conductix.com
translated document
Page 25 of 40
7.5.4
Attachment points
The device must be installed in a system without opening the housing. Opening the housing invalidates any warranty claim.
It is important to ensure that the device is mounted properly and cannot be adversely affected by shock or vibration.
It is also important to ensure that the convection cooling is not restricted by installation on the vehicle.
7.5.5
Additional mechanical protection measure
WARNING!
Risk of burns due to hot, metallic objects!
Metallic objects can be heated inductively. Small parts in particular can get very hot.
→
Always remove small parts, especially those made of ferromagnetic materials, which lie on the ground
in front of the device.
→
For example, integrate a cleaning brush on the vehicle in front of the device to free the inductive
transmission path of small metallic parts.