Resetting the maintenance indication
After completing maintenance work, the
maintenance indication
(yellow LED lights) must be reset
as follows:
• Press drain key
with the unit switched off
and hold down.
• Switch on steam humidifier via the unit switch.
• Hold drain key down until the system test is completed (approx. 10 seconds).
7.5
Notes on cleaning agents
Only use cleaning agents stated in the table above
. The use of disinfectants is only permitted
if they do not leave any toxic residues. In any case the parts must be thoroughly rinsed with water
after cleaning.
WARNING!
Formic acid is indeed harmless to the skin, but it attacks the mucous membranes. Therefore prevent
your eyes and respiratory tracts from getting in touch with the acid and its vapours (wear goggles
and work in a well ventilated room or outside).
CAUTION!
Do not use any solvents, aromatized or halogenized hydrocarbons or other aggressive
substances
as they may cause damage to the components of the unit.
It is mandatory to observe and comply with the information and instructions regarding cleaning agents.
Observe in particular: all information relating to the protection of personnel, environmental protection
and restrictions regarding usage.