7.4
Notes on cleaning the unit components
Unit component
What to clean and how to clean
Steam cylinder cover
Steam cylinder body
Cylinder strainer
• Knock off or brush away any limescale as much as pos
-
sible (do not use a wire brush).
If the parts are heavily calcified, place them in an 8%
formic acid solution (
observe safety notes in chap-
ter 7.5
), until the limescale comes off.
• Finally wash parts in a lukewarm soap solution and rinse
well with tap water.
Heating electrodes
• Immerse the heating electrodes (up to 2 cm below the
snap fastening) in a container with 8-percent formic acid
(
observe safety notes in chapter 7.5
). Allow the acid
to take effect until the limescale has dissolved.
Note: The heating elements do not have to be entirely
free from scale.
• Finally rinse the heating electrodes well with tap water
and let them dry.
CAUTION
: On no account remove limescale from the heat
-
ing electrodes using tools (screw driver, scraper, etc.) or by
striking. This could damage the heating elements!
Water hoses
• Remove any limescale by slightly knocking on the tubes
using a rubber hammer. Then, rinse the tubes well with
hot tap water.
Inlet valve
strainer insert
• Remove strainer insert with pointed pliers. Use a brush
(do not use a wire brush) to remove any limescale.
• Wash strainer insert with a lukewarm soap solution, then
rinse well with tap water.
Let the inlet valve dry before reinstallation!
Содержание EL2
Страница 1: ...Installation and Operating Instructions Electrode Humidifiers 2549892 EN 1112 Condair EL2 ...
Страница 2: ......
Страница 68: ...68 Condair EL2 23 32 32 45 Dimensions in mm ø22 492 670 69 351 180 182 246 180 180 50 547 223 163 118 233 ...
Страница 69: ...69 Notes ...
Страница 70: ...Notes ...
Страница 71: ... Condair Ltd Printed in Switzerland Technical modifications reserved ...