66
10 Product specifications
10.1 Technical data
Heating voltage 230V/1~/50..60Hz
Unit model
5/8
Steam capacity in kg/h
5/8
Max. power consumption in kW
3.8/6.0
Heating voltage 230V/3~/50..60Hz
Unit model
5/8
15
23/32
Steam capacity in kg/h
5/8
15
23/32
Max. power consumption in kW
3.8/6.0
11.2
17.3/22.5
Heating voltage 400V/3~/50..60Hz
Unit model
5/8
15
23/32/45
Steam capacity in kg/h
5/8
15
23/32/45
Max. power consumption in kW
3.8/6.0
11.2
17.3/24.0/33.7
Control voltage
1 x 230V / 50-60 Hz
Operating conditions
Admissible water pressure
1...10 bar
Water quality
Untreated drinking water
with a conductivity of 125...1250 µS/cm
Admissible water temperature
1...40 °C
Admissible ambient temperature
1...40 °C
Admissible ambient humidity
max. 75% rh
Admissible duct air pressure
-0.8 kPa...1.5 kPa; overpressure kit (option) up to 10.0 kPa
Type of protection
IP 20
Conformity
CE, VDE
Dimensions/Weights
Housing (WxHxD) in mm
377x612x279
1
1
492x351x670
1
Net weight in kg
19
19
28
Operating weight in kg
24
30
65
Equipment/options
Steam cylinder type
(Type A.. standard equipment)
A3.../D3...
1
A4.../D4...
1
A6.../D6...
1
Cable gland
CG
1
1
1
Overpressure set
OPS
1
1
1
Remote operating and fault indication
RFI
1
1
1
Terminals heating voltage
M-THV
1
1
L-THV
1
Accessories
Steam distribution pipe
41-...
1
61-...
1
81-...
1
Steam distribution system OptiSorp
System 1
1
1
1
Fan unit
FAN3 EL2 M
1
1
FAN3 EL2 L
1
Steam hose / meter
DS22
1
DS60
1
DS80
1
Condensate hose / meter
KS10
1
1
1
Содержание EL2
Страница 1: ...Installation and Operating Instructions Electrode Humidifiers 2549892 EN 1112 Condair EL2 ...
Страница 2: ......
Страница 68: ...68 Condair EL2 23 32 32 45 Dimensions in mm ø22 492 670 69 351 180 182 246 180 180 50 547 223 163 118 233 ...
Страница 69: ...69 Notes ...
Страница 70: ...Notes ...
Страница 71: ... Condair Ltd Printed in Switzerland Technical modifications reserved ...