RCS20 M:N Redundancy Switch
Revision 15
Remote Operations
MN-RCS20 and CD-RCS20
A–35
A.3.24
Opcode: <2C04h> Command Set Time
Command Data Field (3 bytes):
<1>
Hour
0 - 23
<1>
Minute
0 - 59
<1>
Second
0 - 59
A.3.25
Opcode: <2C05h> Command Set Date
Command Data Field (3 bytes):
<1>
Year
0 – 99
<1>
Month
0 - 11
<1>
Day
0 - 30
A.3.26
Opcode: <2C06h> Command Set Date and Time
Command Data Field (6 bytes):
<1>
Year
0 – 99
<1>
Month
0 - 11
<1>
Day
0 - 30
<1>
Hour
0 - 23
<1>
Minute
0 - 59
<1>
Second
0 - 59