RCS20 M:N Redundancy Switch
Revision 15
Remote Operations
MN-RCS20 and CD-RCS20
A–17
<1>
Latched Switch Minor
Alarms 2
Bit 0 = CDM Error
Bit 1 = Reserved (RCS10 only)
Bit 2 = Reserved (RCS10 only)
Bit 3 = Reserved (RCS10 only)
Bit 4 = Backup 1 Test Fault
Bit 5 = Backup 2 Test Fault
Bit 6 = Reserved (RCS10 only)
Bit 7 = Spare
(0 = no alarm, 1 = alarm)
<1>
Backup 1 Mod Hot
Standby Channel
Channel number (1 to 9) (0 = No hot standby for backup 1 mod)
<1>
Backup 1 Demod Hot
Standby Channel
Channel number (1 to 9) (0 = No hot standby for backup 1 Demod)
<1>
Backup 2 Mod Hot
Standby Channel
Channel number (1 to 8) (0 = No hot standby for backup 2 mod, or
channel 9 not configured as backup)
<1>
Backup 2 Demod Hot
Standby Channel
Channel number (1 to 8) (0 = No hot standby for backup
2 Demod, or Channel 9 not configured as backup
A.3.2
Opcode <2002h> Query RCS20 Switch Configuration
Query Response Data Field (285 bytes)
Configuration Bytes
<2>
Nonvolatile Bytes
Number of nonvolatile RCS20 configuration memory bytes, including
these 2 bytes (221 decimal for RCS20)
<1>
Number of Channels
Maximum number of prime and backup channels available to the
RCS20 switch. (10 decimal for RCS20 as of Release 1.0)
<1>
Nonvolatile Bytes per
Channel
Number of nonvolatile memory bytes per channel. This number may
vary with the release number. (10 bytes for RCS20 as of release 1.0
and 13 bytes as of release 4.0)
**Remote M&C developers must make use of this value to find out how many bytes
per channel are being transmitted.
<1>
*Channel 0
Configuration
Bit 0 = Modulator present
Bit 1 = Demodulator present
(0 = not present, 1 = present)
Содержание Radyne RCS20
Страница 132: ...RCS20 M N Redundancy Switch Revision 15 Electrical Interfaces MN RCS20 and CD RCS20 5 34 BLANK PAGE...
Страница 136: ...RCS20 M N Redundancy Switch Revision 15 Maintenance and Troubleshooting MN RCS20 and CD RCS20 6 4 BLANK PAGE...
Страница 176: ...RCS20 M N Redundancy Switch Revision 15 Remote Operations MN RCS20 and CD RCS20 A 36 BLANK PAGE...
Страница 196: ...RCS20 M N Redundancy Switch Revision 15 System Cabling Configuration MN RCS20 and CD RCS20 B 20 BLANK PAGE...
Страница 199: ...BLANK PAGE...
Страница 200: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...