RCS20 M:N Redundancy Switch
Revision 15
User Interfaces
MN-RCS20 and CD-RCS20
4–58
4.3.3.7
SWITCH MINOR ALARMS 1
These screens display the RCS20 minor alarms, and allow the user to mask these alarms. When an
alarm is masked, the error will not be reported on the front panel MINOR ALARM Lamp or on the ALARM
connector at the rear of the RCU20. The POWER SUPPLY 1 PRESENT Alarm indicates that slide-in
Power Supply Module 1 is fully seated in the RCU20. The POWER SUPPLY 1 VOLTAGE Alarm indicates
a voltage problem with slide-in Power Supply Module 1. The remaining two alarms indicate the same
conditions for slide-in Power Supply Module 2.
CAUTION
Masking alarms may cause undesirable modem performance
4.3.3.7.1
Programming steps:
1.
Press
or
to move the flashing cursor the channel to be programmed
2.
Press <TOG MODE> to toggle between YES and NO. ‘Y’ indicates an alarm is masked, ‘N’
indicates an alarm is not masked.
3.
Press <CLR> or <NEXT> to abort programming (no switch parameters changed).
4.
Press <ENT> to load the information on the screen into the switch parameter table.
Key
Label
Function
S1
Press to move the blinking cursor up through the list of faults.
S2
Press to move the blinking cursor down through the list of faults.
S3
TOG MODE Used to toggle between YES (masked) and NO (not masked).
S4
NEXT
Press to cycle to the next screen.
Numeric Keypad ---
Press <CLR> or <NEXT> to abort programming (no switch parameters changed).
Press <ENT> to load the information on the screen into the switch parameter table.
SWITCH MINOR ALARMS
MASK
POWER SUPPLY 1 PRESENT : FAIL YES
POWER SUPPLY 1 VOLTAGE : FAIL YES
POWER SUPPLY 2 PRESENT : PASS NO
POWER SUPPLY 2 VOLTAGE : PASS NO
TOG MODE NEXT
<FT PANEL> <TERM> <COMPUTER> NEXT
Содержание Radyne RCS20
Страница 132: ...RCS20 M N Redundancy Switch Revision 15 Electrical Interfaces MN RCS20 and CD RCS20 5 34 BLANK PAGE...
Страница 136: ...RCS20 M N Redundancy Switch Revision 15 Maintenance and Troubleshooting MN RCS20 and CD RCS20 6 4 BLANK PAGE...
Страница 176: ...RCS20 M N Redundancy Switch Revision 15 Remote Operations MN RCS20 and CD RCS20 A 36 BLANK PAGE...
Страница 196: ...RCS20 M N Redundancy Switch Revision 15 System Cabling Configuration MN RCS20 and CD RCS20 B 20 BLANK PAGE...
Страница 199: ...BLANK PAGE...
Страница 200: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...