RCS20 M:N Redundancy Switch
Revision 15
User Interfaces
MN-RCS20 and CD-RCS20
4–56
Key
Label
Function
S4
NEXT
Press to cycle to the next Events Screen.
Numeric Keypad ---
N/A
4.3.3.4
NEXT EVENTS SCREEN
Key
Label
Function
S1
DELALL Press to delete all stored events.
S2
---
N/A
S3
---
N/A
S4
NEXT
Press to cycle to the next screen.
Numeric Keypad ---
N/A
4.3.3.5
SWITCH MAJOR ALARMS 1
These screens display the RCS20 major alarms, and allow the user to mask these alarms. When an
alarm is masked, the error will not be reported on the front panel MAJOR ALARM lamp nor on the
ALARM connector at the rear of the RCS20. The RAM/ROM alarm indicates a failure of the RCS20
internal memory. The BACKUP UNAVAILABLE alarm indicates that a prime channel modem has failed,
but there was no backup channel modem available for backup, causing prime channel traffic to be
dropped. The BACKUP ERROR alarm indicates that the prime channel modem configuration could not be
loaded to a backup channel modem, thus a required automatic backup could not take place, causing
prime channel traffic to be dropped.
CAUTION
Masking alarms may cause undesirable modem performance
4.3.3.5.1
Programming steps:
1.
Press
or
to move the flashing cursor the channel to be programmed
SWITCH MAJOR ALARMS
MASK
RAM/ROM : PASS NO
BACKUP UNAVAILABLE : FAIL NO
ERROR DURING <BACKUP> : FAIL YES
Y/N NEXT
Содержание Radyne RCS20
Страница 132: ...RCS20 M N Redundancy Switch Revision 15 Electrical Interfaces MN RCS20 and CD RCS20 5 34 BLANK PAGE...
Страница 136: ...RCS20 M N Redundancy Switch Revision 15 Maintenance and Troubleshooting MN RCS20 and CD RCS20 6 4 BLANK PAGE...
Страница 176: ...RCS20 M N Redundancy Switch Revision 15 Remote Operations MN RCS20 and CD RCS20 A 36 BLANK PAGE...
Страница 196: ...RCS20 M N Redundancy Switch Revision 15 System Cabling Configuration MN RCS20 and CD RCS20 B 20 BLANK PAGE...
Страница 199: ...BLANK PAGE...
Страница 200: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...