RCS20 M:N Redundancy Switch
Revision 15
User Interfaces
MN-RCS20 and CD-RCS20
4–50
4.3.2.25
RDM FALLBACK CONFIGURATION
This screen allows the user to configure the fallback programming for the optional Reference Distribution
Module (RDM). The RDM has two reference inputs (EXTA, EXTB) and an internal frequency source
(INT). The fallback programming allows automatic switching between these three frequency sources.
There are clock activity detectors on each frequency source, and automatic switching (fallback) will occur
if there is no activity for the current frequency source. The following fallback modes are available:
EXTA ONLY
INT ONLY
EXTA
INT
INT
EXTA
EXTA
EXTB
EXTA
EXTB
INT
INT
EXTA
EXTB
For these modes, the system will switch to the leftmost source that has clock activity. For example, if the
fallback mode is EXTA
EXTB
INT, and there is no activity on EXTA or EXTB, then the INT source
will be selected. If activity returns to EXTB, then EXTB will be selected, and if activity returns to EXTA,
then EXTA will be selected.
4.3.2.25.1
Programming steps:
1.
Press <TOG MODE> to change the displayed fallback mode.
2.
Continue pressing <TOG MODE> until the desired fallback mode is displayed.
3.
Press <CLR> or <RETURN> to abort programming (no switch parameters changed).
4.
Press <ENT> to load the information on the screen into the switch parameter table.
Key
Label
Function
S1
TOG MODE Cycle through the above listed fallback configurations.
S2
---
N/A
S3
---
N/A
S4
RETURN
Cycle back to the REFERENCE DISTRIBUTION CONFIGURATION Screen.
Numeric Keypad ---
Press <CLR> or <RETURN> to abort programming (no parameters changed).
Press <ENT> to load the information on the screen into the switch parameter table.
RDM INTERNAL REFERENCE CONFIGURATION
FALLBACK : EXTA ONLY
TOG MODE RETURN
Содержание Radyne RCS20
Страница 132: ...RCS20 M N Redundancy Switch Revision 15 Electrical Interfaces MN RCS20 and CD RCS20 5 34 BLANK PAGE...
Страница 136: ...RCS20 M N Redundancy Switch Revision 15 Maintenance and Troubleshooting MN RCS20 and CD RCS20 6 4 BLANK PAGE...
Страница 176: ...RCS20 M N Redundancy Switch Revision 15 Remote Operations MN RCS20 and CD RCS20 A 36 BLANK PAGE...
Страница 196: ...RCS20 M N Redundancy Switch Revision 15 System Cabling Configuration MN RCS20 and CD RCS20 B 20 BLANK PAGE...
Страница 199: ...BLANK PAGE...
Страница 200: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...