RCS20 M:N Redundancy Switch
Revision 15
User Interfaces
MN-RCS20 and CD-RCS20
4–31
Key
Label
Function
Numeric Keypad ---
Press <NEXT> to advance to next screen.
Press <CLR> to return to previous screen.
4.3.2.2
TERMINAL PORT CONFIGURATION
This screen displays both the Terminal Baud Rate and the Terminal Emulation Type, and allows the user
to cycle to Subscreens to change the configurations. The baud rate may be any of the following:
•
19200
•
9600
•
2400
The emulation type may be any of the following:
•
ADDS VP
•
VT 100
•
WYSE 50
4.3.2.2.1
Programming steps:
1.
Press <BAUD> to cycle to the TERMINAL PORT BAUD RATE Subscreen to change the
configuration. Press <EMUL> to cycle to the TERMINAL PORT EMULATION Subscreen to
change the configuration.
IMPORTANT
After changing the Terminal Port Baud Rate, power must be cycled before the baud
rate change takes effect.
Key
Label
Function
S1
BAUD Press to cycle to the TERMINAL PORT BAUD RATE Subscreen.
S2
EMUL Press to cycle to the TERMINAL PORT EMULATION Subscreen.
TERMINAL PORT CONFIGURATION
TERMINAL BAUD RATE : 19200
TERMINAL EMULATION : VT 100
BAUD EMUL NEXT
Содержание Radyne RCS20
Страница 132: ...RCS20 M N Redundancy Switch Revision 15 Electrical Interfaces MN RCS20 and CD RCS20 5 34 BLANK PAGE...
Страница 136: ...RCS20 M N Redundancy Switch Revision 15 Maintenance and Troubleshooting MN RCS20 and CD RCS20 6 4 BLANK PAGE...
Страница 176: ...RCS20 M N Redundancy Switch Revision 15 Remote Operations MN RCS20 and CD RCS20 A 36 BLANK PAGE...
Страница 196: ...RCS20 M N Redundancy Switch Revision 15 System Cabling Configuration MN RCS20 and CD RCS20 B 20 BLANK PAGE...
Страница 199: ...BLANK PAGE...
Страница 200: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...