background image

LGAN 

Outdoor Amplifier / Block Up Converter (BUC) 

Installation and Operation Manual 

Part Number

 MN-LGAN

 

Revision

 

0

 

IMPORTANT NOTE:  The information contained in this document supersedes all previously published 

information regarding this product. Product specifications are subject to change without prior notice.

Содержание LGAN

Страница 1: ...ation and Operation Manual Part Number MN LGAN Revision 0 IMPORTANT NOTE The information contained in this document supersedes all previously published information regarding this product Product speci...

Страница 2: ...2020 Comtech EF Data All rights reserved Printed in the USA Comtech EF Data 2114 West 7th Street Tempe Arizona 85281 USA 480 333 2200 FAX 480 333 2161 Revision History Rev Date Description 0 Feb 2020...

Страница 3: ...tor and Control M C 1 2 1 3 3 Enhanced Standard Features 1 2 1 3 4 Smart BUC Functionality 1 2 1 3 5 Data Logging Capability 1 3 1 3 6 Optional Internal 10 MHz Reference 1 3 1 3 7 Optional LNB Support...

Страница 4: ...ired User supplied Items 3 2 3 2 1 1 LGaN Connections 3 3 3 2 2 LGaN Management IP Address and Firmware Information 3 3 3 2 2 1 Locate Firmware Information via HTTP Interface 3 3 3 3 Download and Extr...

Страница 5: ...ional Parameters Common Commands and Queries 5 2 5 2 1 Faults 5 2 5 2 2 Common Commands 5 2 5 3 Remote Control Protocol and Structure 5 3 5 3 1 EIA 232 5 3 5 3 2 EIA 485 5 3 5 3 3 EIA 485 Full Duplex...

Страница 6: ...ure Tera Term 4 7 Figure 4 4 Open Windows Command line 4 8 Figure 4 5 Telnet Login and Remote Command Execution 4 9 Figure 4 6 LGaN HTTP Interface Splash Page Example 4 10 Figure 4 7 LGaN HTTP Interfa...

Страница 7: ...oise Block Down Converter 1 1 LRS Local Remote Status 4 8 M C Monitor and Control 1 2 MCP Monitor Control Processor 1 2 MIB Management Information Base 4 1 MOP Maximum Operating Point 4 26 MTBF Mean T...

Страница 8: ...Decibels relative to the carrier dBm Decibel milliwatts F Fahrenheit degrees Kbps Kilobit per second kg kilogram ksps Kilosymbols per second lbs pounds mA Milli amp Mbps Megabit per second MHz Megaher...

Страница 9: ...his equipment All statements technical information and recommendations in this manual and in any guides or related documents are believed reliable but the accuracy and completeness thereof are not gua...

Страница 10: ...ou to important operational information or details furnished elsewhere either in the manual or in adjunct Comtech EF Data publications Examples of Multi Hazard Notices Recommended Standard Designation...

Страница 11: ...GaN does have built in surge suppression if the unit is to be installed in a location with questionable power grid quality Comtech EF Data recommends installation of additional power conditioning surg...

Страница 12: ...Product Support For all product support please call 1 240 243 1880 1 866 472 3963 toll free USA Comtech EF Data Headquarters http www comtechefdata com Comtech EF Data Corp 2114 West 7th Street Tempe...

Страница 13: ...t under warranty the owner is responsible for freight to Comtech EF Data and all related customs taxes tariffs insurance etc Comtech EF Data is responsible for the freight charges only for return of t...

Страница 14: ...acement The warranty excludes any responsibility by Comtech EF Data Corporation for incidental or consequential damages arising from the use of the equipment or products or for any inability to use th...

Страница 15: ...r Traveling Wave Tube TWT amplifiers in satellite communications CEFD s extensive experience in the design of outdoor Radio Frequency RF transceivers led to the LGaN family s efficient thermal and mec...

Страница 16: ...essential parameters of the unit The user interfaces with the unit through the M C system via the remote control discrete communications port The unit is capable of EIA 232 EIA 485 or Ethernet remote...

Страница 17: ...od voltage standing wave ratio VSWR The RF signal then passes through an electronically controlled attenuator that adjusts the overall attenuation according to the user input After some amplification...

Страница 18: ...and is very close to the actual ambient or outside temperature This temperature can be monitored on the Status Status webpage It is also reported via the serial RMS command and has the label of Outsi...

Страница 19: ...until the alarm clears and the estimated overdrive is 0 dB Note that once the over drive alarm is active the input power level must be reduced until the output power is 5 dB below the Prated level bef...

Страница 20: ...t C Band 6725 to 7025 MHz 5760 MHz No X Band 7900 to 8400 MHz 6950 MHz No Ku Band Low 12 75 to 13 25 GHz 11 800 GHz No Ku Band 14 00 to 14 50 GHz 13 050 GHz No Ku Band W 13 75 to 14 50 GHz 12 800 GHz...

Страница 21: ...figures in each subsection all dimensions are in inches Bracketed dimensions where shown are in metric units mm Unless otherwise noted all figures depict AC Option Waveguide Output units 1 4 1 LGaN 5...

Страница 22: ...L GaN Revision 0 Introduction 1 8 Figure 1 4 LGaN 50 W Dimensional Envelope 2 of 2...

Страница 23: ...L GaN Revision 0 Introduction 1 9 1 4 2 LGaN 100 W Dimensional Envelopes Figure 1 5 LGaN 100 W Ku Band Dimensional Envelope 1 of 2...

Страница 24: ...L GaN Revision 0 Introduction 1 10 Figure 1 6 LGaN 100 W Ku Band Dimensional Envelope 2 of 2...

Страница 25: ...FACE OPERATION See for information about using serial based remote commands and queries Appendix A 1 1 REDUNDANCY See for detailed information for installing and using the LGaNs in a 1 1 redundancy co...

Страница 26: ...he external connector housing and extend beyond the end of the heatshrink that covers the connector termination of the cable assembly Squeeze the self amalgamating tape tightly and make sure both ends...

Страница 27: ...MN LGAN 2 3 Connectors and Cables The LGaN external connectors provide all necessary connections between the LGaN 50 W Figure 2 1 or the LGaN 100 W Figure 2 2 models and other equipment Figure 2 1 LG...

Страница 28: ...ar Connector Example Connection Instructions Engage all the alignment and lock features between the male connector on the interconnection cable and female socket To install the male connector into the...

Страница 29: ...OUTPUT The J2 RF OUT connector will be waveguide appropriate to the frequency of the unit Connector J3 POWER IN AC Power Mains FOR SAFETY REASONS MAKE SURE YOU KNOW THAT THE J3 POWER IN AC POWER CONNE...

Страница 30: ...KNOW THAT THE J3 POWER IN DC POWER CONNECTION PIN ASSIGNMENTS ARE DIFFERENT FOR EACH LGAN UNIT YOU MUST USE THE CORRECT PIN ASSIGNMENTS INCORRECT USE OF PIN ASSIGNMENTS CAN RESULT IN PRODUCT DAMAGE OR...

Страница 31: ...D V 2 3 3 2 2 Connector J3 POWER IN DC Power Main 100 W The mating connector specification and the pin assignments specific to the LGaN 100 W DC power interface are as follows Mating Connector ITT Ca...

Страница 32: ...le connector F Ethernet TX Pin 3 of RJ45 female connector G RS232_TD Pin 2 of DB9 female connector H Ethernet TX Pin 6 of RJ45 female connector J TX RX Switch Drive 1 Pos Not for customer use K GND Gr...

Страница 33: ...its 2 3 6 Connector J11 LNB 100 W The LNB input connector is a Type N connector used for LNB Bias on 100 W units 2 3 7 Ground Connector Use this 10 32 hardware available where shown in Figure 2 4 to c...

Страница 34: ...ply Cable 50 W Mating connectors are provided OPTIONAL As an alternate the following cable can be purchased from Comtech EF Data part number CA 0021705 2 3 8 2 DC Power Supply Cable 100 W Mating conne...

Страница 35: ...d on the accompanying USB memory stick 2 4 LGaN Power FOR SAFETY REASONS NEVER TURN THE UNIT ON WITHOUT PROPER WAVEGUIDE TERMINATION ON THE J2 RF OUT PORT YOU MAY OTHERWISE BE EXPOSED TO DANGEROUSLY H...

Страница 36: ...LGaN Revision 0 System Connectors Installation and Startup 2 12 MN LGAN BLANK PAGE...

Страница 37: ...er PC using one of the methods described in Section 3 2 1 1 The PC is running a terminal emulation program for operation of the LGaN Serial or Ethernet Telnet interfaces The LGaN Management IP Address...

Страница 38: ...where there is another tab for Download Flash Software Update Files The LGaN is listed under Amplifiers Once the LGaN page is opened the LGaN firmware download hyperlink appears as FW 0021193X_V wher...

Страница 39: ...and Firmware Information do these steps 1 On the LGaN apply power to the unit Refer to Chapter 2 Section 2 2 3 or 2 2 4 to identify your specific power connector 2 Identify your default Management IP...

Страница 40: ...e Use the WinZip features to select the files for extraction to your destination folder o Click Save to download the ZIP file to your Windows Downloads folder Once the download is complete the dialogu...

Страница 41: ...or remote M C of the LGaN Telnet Interface You may use the serial remote control protocol via this interface This requires use of Windows Command line or a user supplied terminal emulation program suc...

Страница 42: ...D provides remote management of a particular function These MIB files should be compiled in a user supplied MIB Browser or SNMP Network Monitoring System server In the LGaN MIB file names the letter x...

Страница 43: ...n of the LGaN M C See the LGaN Firmware Release Notes for information on the required Firmware Software FW SW compatibility 4 2 3 SNMP Traps The LGaN SNMP agent supports both SNMPv1 and v2c The LGaN T...

Страница 44: ...1 6247 48 1 3 1 2 LGaNPowerSupplyLNBStatus 1 3 6 1 4 1 6247 48 1 3 1 3 LGaNPowerSupply13VStatus 1 3 6 1 4 1 6247 48 1 3 1 4 LGaNPowerSupply10VStatus 1 3 6 1 4 1 6247 48 1 3 1 5 LGaNRFPowerSupply10V1S...

Страница 45: ...1 3 6 1 4 1 6247 48 1 3 1 19 LGaNFPGADoneStatus 1 3 6 1 4 1 6247 48 1 3 1 20 LGaNBUCLockDetectStatus 1 3 6 1 4 1 6247 48 1 3 1 21 LGaNRefLockDetectStatus 1 3 6 1 4 1 6247 48 1 3 1 22 LGaNLNBCSStatus...

Страница 46: ...trol Interface An example of the login process and remote control operation is shown here Figure 4 1 Telnet Interface Example Windows Command line 4 3 1 Telnet Remote Control Operation via HyperTermin...

Страница 47: ...onfigure Tera Term See Figure 4 3 Do these steps 1 Make sure to define the Connect To Telnet connection properties correctly new connection prompt is displayed when Tera Term is started Figure 4 3 a E...

Страница 48: ...GaN using only a 100BaseTx remote interface this assumes that you are running a Microsoft Windows operating system See Figure 4 4 and do these steps 1 Select Start then Run then type cmd to open the W...

Страница 49: ...yy where xxx xxx xxx xxx is a valid IP address on the network where the unit is to be installed and yy is the range typically yy 24 Changing the IPA value requires that you cycle power on the unit an...

Страница 50: ...mple 4 4 3 HTTP Interface Features 4 4 3 1 Menu Tree Home Admin Config Status Home Access Amplifier Summary Contact Time LNB Status Support SNMP Mask FETs Update Utility Events MOP Statistics Trending...

Страница 51: ...ad only displays for a specific function 4 4 4 3 Action Buttons Action buttons are important in the LGaN HTTP Interface Click an action button to do one of these tasks Click Refresh to see the latest...

Страница 52: ...figures provided in this section are intended for reference purposes only Your setup may differ from what is shown in this section 4 5 1 Home Pages Click Home or Contact to continue 4 5 1 1 Home Home...

Страница 53: ...LGaN Revision 0 Ethernet Interface Operation 4 13 MN LGAN 4 5 1 2 Home Contact For all product support please call 1 240 243 1880 1 866 472 3963 toll free USA Figure 4 9 Home Contact Page...

Страница 54: ...lick Access Time SNMP or Upgrade to continue 4 5 2 1 Admin Access Click Refresh to see the latest page data Figure 4 10 Admin Access Page Network Maintenance Name Description IP Gateway Enter the desi...

Страница 55: ...e Name The factory default is opcenter Read Write Password The factory default is 1234 Admin Name The factory default is comtech Admin Password The factory default is comtech Session Timeout Number of...

Страница 56: ...list to select Enabled or Disabled Trap IP 1 The Administrator can assign up to two SNMP Trap IP Addresses Trap IP 2 The Administrator can assign up to two SNMP Trap IP Addresses Trap Version Use the...

Страница 57: ...Zip File Upload File Button Used to upload the Firmware Zip File Extract Files Button Used to extract the Firmware File from the Zip File Click Submit to save any changes Firmware Image Name Descript...

Страница 58: ...in 0 25 dB steps Attenuation Offset Enter a valid offset value in dB 00 00 to 20 00 dB in 0 25 dB steps Used for Redundancy s offline unit to match Tx Gain to the online unit Displayed only when Redu...

Страница 59: ...wer drops below the specified value the alarm fault occurs Click Submit Thres to save any changes Reference Name Description Ref Freq Adjust Enter a valid reference oscillator tuning voltage value fro...

Страница 60: ...LNB current draw Any LNB current reading that is outside the window may generate an alarm a fault or may be masked entirely depending on the state of the user configured fault mask see the MSK comman...

Страница 61: ...dle a Fan Event External Reference Lock How to handle a External Reference Lock loss Max Reverse Power User sets the threshold see Configuration Amplifer Display only if equipped RF Fan 1 Speed How to...

Страница 62: ...y Page Circuit ID Name Description Circuit ID Enter a Circuit ID unit identification label string of up to 48 characters This is the identification label for the unit Click Change CID to save the chan...

Страница 63: ...d If a fault exists the Summary Fault message changes to FAULT on a red background Should this occur review the logged faults and alarms on the Status Events page see Sect 4 5 4 4 Terminal Status Chan...

Страница 64: ...eral status data for the LGaN The Status Status page updates automatically once every 5 seconds Some fields will display only if equipped e g If the system doesn t have an Internal Reference and LNB a...

Страница 65: ...Status FETs Use this read only page to monitor the current operating status of the LGaN s Qx RF Power Field Effect Transistors FETs that are installed in the RF amplifier Each LGaN product type will h...

Страница 66: ...0 Ethernet Interface Operation 4 26 MN LGAN 4 5 4 4 Status Events Use this page to see stored events data The whole Event log is displayed Click Refresh to see the latest page data Figure 4 21 Status...

Страница 67: ...ace Operation 4 27 MN LGAN 4 5 4 5 Status MOP This page shows the Maximum Operating Points MOPs Maximum and some Minimum values of critical monitored parameters Click Refresh to see the latest page da...

Страница 68: ...me Description Statistics Interval Enter the interval at which statistics are logged The interval is set in minutes Minimum resolution is 1 minute 001 maximum is 99 minutes 099 Default is 60 minutes 0...

Страница 69: ...LGaN Revision 0 Ethernet Interface Operation 4 29 MN LGAN 4 5 4 7 Status Trending Click Refresh to see the latest graph data Figure 4 24 Status Trending Graphs Page...

Страница 70: ...ration for 24 hours only present will be available Time Once a unit has been in operation for 24 hours or more use this drop down list to select the time on the hour 24 hours from 12 am to 11 pm are a...

Страница 71: ...in the unit the red line graphs the Ambient outdoor temperature Check or uncheck a checkbox to control the graphing of either temperature The graph will update dynamically after the next polling cycle...

Страница 72: ...ly if an LNB is connected to the system and is drawing current from the LNB current source Amplifier Status Graph This graph displays the state of the RF amplifier On Off As per this example On is rep...

Страница 73: ...ic at 0 zero indicates an unmuted condition A logic at 1 negative one displays when data is unavailable Check or uncheck a checkbox to control the graphing of either muting function The graph will upd...

Страница 74: ...tem This example demonstrates the fan running at minimum proportional and maximum speeds Note that Proportional fan speed Proportional to the unit s heat sink temperature 5 to 15 C 23 to 59 F Minimum...

Страница 75: ...e the LGaN with its latest available firmware 5 1 Overview Serial based remote management of CEFD s LGaN family of Outdoor Amplifiers Block Up Converters BUCs is available using the J6 COM1 port This...

Страница 76: ...nit to mute itself and switch to the back up unit if in a redundant system However the 10V supply to the FET transistors will remain on until the unit reaches the thermal shutdown temperature of 100 C...

Страница 77: ...data is carried in the other direction on the other conductor 5 3 2 EIA 485 For applications where multiple devices are to be monitored and controlled a full duplex 4 wire EIA 485 is preferred Half d...

Страница 78: ...ynchronous character format is fixed at 8N1 8 data bits No parity and 1 stop bit Baud rates 2400 4800 9600 19200 and 38400 are supported All data is transmitted in framed packets The host controller i...

Страница 79: ...ion of an instruction to change the configuration of the Target Controller to Target Start of Packet Target Address Address Delimiter Instruction Code Code Qualifier Optional Arguments End of Packet A...

Страница 80: ...r sends a packet with the address of a target the destination of the packet When the target responds the address used is the same address to indicate to the controller the source of the packet The con...

Страница 81: ...ith no message arguments ASCII code 63 If the controller sends an instruction to set a parameter to a particular value and if the value sent is not valid the target will acknowledge the message by rep...

Страница 82: ...ation of a packet Controller to Target This is the Carriage Return character ASCII code 13 Target to Controller This is the two character sequence Carriage Return Line Feed ASCII code 13 and code 10 5...

Страница 83: ...as Command only Query only or Command or Query Where CODE XXX this indicates a priority command 2 In the tables that follow the following codes are used in the Response to Command column per Sect 8 5...

Страница 84: ...MUT X X 5 22 SBR X X 5 30 TMP X 5 33 AUX X X 5 12 IMG X X 5 16 NUE X 5 22 SBT X X 5 31 TNA X 5 34 CAA X 5 12 IPA X X 5 17 NUS X 5 22 SFS X 5 31 TNE X 5 34 CAE X 5 12 IPG X X 5 17 PNM X 5 22 SNA X X 5...

Страница 85: ...ns clear 0 Automatic fault recovery disabled unit will remain muted until the user un mutes the output using the MUT command Example 0001 AFR 1 cr 0001 AFR cr lf Default Value 1 AFR AFR AFR AFR x Same...

Страница 86: ...TT 10 00 cr 0001 ATT cr lf Default Value 10 00 Default ATT Step 0 25 dB ATT ATT ATT ATT ATT xx xx Same format as command arguments Auxiliary Mute AUX 1 byte Command or Query Enable or disable the auxi...

Страница 87: ...1 cr lf Default Value CUSTOMER ID MESSAGE CID CID CID CID CID x x See description for details of arguments Calibrate LNB Current CLC N A Command or Query The CLC command stores the value of the LNB Cu...

Страница 88: ...nd in the form mmddyy where dd day of the month between 01 and 31 mm month of the year between 01 and 12 and yy year between 00 and 96 1K OD to 2096 Example date April 24 2003 1 DAT 042503 cr 0001 DAT...

Страница 89: ...The firmware information is returned in the following format FW AAAAAAA B B BB DD MM YY Where FW AAAAAAA the firmware part number B B BB the version number DD MM YY Day Month Year firmware released Ex...

Страница 90: ...the 1kW it was 40 60 dBm Example 1 HPT 56 00 cr 0001 HPT cr lf Default Value 00 00 HPT HPT HPT HPT High Power Threshold Initialize Events Pointer IEP None Command only Resets internal pointer to allo...

Страница 91: ...address through the Telnet interface requires the user to power cycle the unit and then restart a new Telnet session with the new IP address The IP address typed into the Telnet client software does n...

Страница 92: ...be calibrated 0 Disable 1 Enable Example 1 LCS 1 cr 0001 LCS cr lf Default Value 0 LCS LCS LCS LCS LCS x Same format as command arguments LNB Current Window LCW 2 bytes Command or Query This command a...

Страница 93: ...0001 LPT 00 00 cr 0001LPT cr lf Default Value 00 00 LPT LPT LPT LPT LPT xxx x Same format as command arguments Local Remote State LRS 1 byte Command or Query Set Local or Remote for Indoor SSPA Always...

Страница 94: ...MP Exhaust Temperature dec C 250W RF40I RF 40V current amps 250W RF24I 24V RF current 50W 100W PS24I 24V PS current AC Volt AC Vrms 100W 250W AC Curr AC Irms amps 100W 250W AC VPEAK AC Volt Peak 100W...

Страница 95: ...ommand or Query Alarm mask conditions If the mask value for a certain parameter is set to fault then a fault condition will be registered if specified hardware conditions are not met If the mask value...

Страница 96: ...bytes Query only Unit returns the Number of stored Events which remain Unread in the form of xxx Example 1 NUE cr 0001 NUE 126 cr lf NUE NUE NUE xxx Number of Unread Stored Statistics N A 3 bytes Quer...

Страница 97: ...VPWR System Reverse Power 100W 250W SYS INPWR System Input Power 250W SYS INTMP Internal Temperatures SYS OTEMP Outside Temperatures 100W 250W SYS RFOVR RF Overdrive SYS BUCLD BUC Lock Detect SYS XRFL...

Страница 98: ...m Status cont PS PS24I 24V current Power Supply PS PS13V 13 5V Power Supply PS P5V8T 5 8V Power Supply PS P5V0T 5 0V Power Supply PS P3V3T 3 3V Power Supply PS PN5V8 5 8V Power Supply PS PFAN1 Power S...

Страница 99: ...description for details of arguments Retrieve Configuration Status N A Query only Used to query the configuration status of the unit Where AMP RF power amplifier state 0 OFF 1 ON MUT RF mute state 0 u...

Страница 100: ...d in the unit Example 1 RET cr 0001 RET TRP500 4450 C OD VER 1 1 1 cr lf RET RET RET x x See description for details of arguments RF Power FET Current Status N A Variable length depending on the numbe...

Страница 101: ...Voltage 250W VRMS AC Vrms Voltage 100W 250W Irms AC Irms Current 100W 250W Vpeak AC Peak Voltage 100W 250W Watts AC Watts 100W 250W AC_VA AC VA 100W 250W AC_PF AC Power Factor 100W 250W LFREQ AC Line...

Страница 102: ...nly Unit returns the oldest 5 Stored Events which have not yet been read over the remote control Reply format CR Sub body CR Sub body CR Sub body CR Sub body CR Sub body Where Sub body ddmmyyhhmmssABC...

Страница 103: ...date HH MM SS entry time a amplifier enable state 1 on 0 off b mute enable state 1 on 0 off c Online state 1 online 0 offline dd dd RF attenuation dB ee e forward power monitor dBm ff f Reverse Power...

Страница 104: ...RUS RUS x x See description for details of arguments Summary Alarm Status N A 1 byte Query only Indicates if there are any active alarm conditions SAS x Where 0 no active alarms 1 at least one active...

Страница 105: ...ute LNB Example 1 SBT 1 Note To send this command the unit must have the bias tee option installed otherwise a mode error will result A mode error will also result if this command is sent while the un...

Страница 106: ...between 0001 to 9999 Resolution 0001 Example 1 SPA 0412 cr 0001 SPA cr lf Default Value 0001 SPA SPA SPA xxxx Same format as command arguments SNMP Read Community SRC 16 bytes characters no spaces Com...

Страница 107: ...on STV 1 byte Command or Query SNMP Trap Version that will be used to send traps 1 SNMP Trap Version 1 2 SNMP Trap Version 2 Example 1 STV 0 STV STV STV STV x See description of arguments SNMP Write C...

Страница 108: ...uments Total Number of Events N A 2 bytes Query only Returns the number of unread entries in the stored events log Example 1 TNE cr 0001 TNE 14 cr lf TNE TNE TNE xx See description for details of argu...

Страница 109: ...figure illustrates the cable s technical specifications e g connector types used cable labeling wiring lists etc The tables in this appendix cross reference cable use in LGaN Standalone applications T...

Страница 110: ...A 1 A 3 A 12 through A 30 Figure A 2 CA 0000352 Ethernet Interface Cable 19 pin circular connector to 2X RJ 45 Connecting Standalone LGaN J6 COM1 receptacle to LGaNnet Ethernet jack Cable and LGaNnet...

Страница 111: ...d control of 1 1 Redundancy or Standalone LGaN applications using the CLC 10 CEFD LGaN Controller a preconfigured Two Technologies Inc TechTerm Handheld Terminal The circular connector installs onto t...

Страница 112: ...available to provide Ethernet based M C of Standalone LGaN applications using a Samsung NB30 Plus Netbook LGaNnet The P1 circular connector installs onto the J6 COM 1 connector on a Standalone LGaN Us...

Страница 113: ...ision 0 Appendix A A 5 MN LGAN A 2 3 19 Pin COMMS Cable 100 This cable connects between the designated data interface and the J6 COM 1 port on a Standalone LGaN Figure A 3 COMMS Cable 100 CEFD P N CA...

Страница 114: ...ision 0 Appendix A A 6 MN LGAN A 2 4 19 Pin COMMS Cable 250 This cable connects between the designated data interface and the J6 COM 1 port on a Standalone LGaN Figure A 4 COMMS Cable 250 CEFD P N CA...

Страница 115: ...ix A A 7 MN LGAN A 3 RF Cables FIG CEFD CABLE P N DESCRIPTION USED FOR REF App A FIG Figure A 5 CA 3722 X Type N to Type N 1 4 Heliax Coaxial Cable lengths vary LGaN Rx or Tx connections in Standalone...

Страница 116: ...GaN 100 W C Band and X Band applications For Standalone use the cable connects the unit s J2 RF OUT port directly to your Rx signal destination For all LGaN applications For Standalone use the cable c...

Страница 117: ......