2. The appliance coupler (that is, the connector to the device
itself, not the wall plug) must have a configuration for
mating with a EN60 320 appliance inlet (Standard Sheet
C14).
3. The length of the cord set must be as follows:
❏
Minimum: 6.50 ft (2.0 m)
❏
Maximum: 9.75 ft (3.0 m)
U.S. and Canada
1. The cord set must be UL-Listed and CSA-Certified.
2. The minimum specifications for the flexible cord are:
❏
No. 18 AWG
❏
Type SJ
❏
3-conductor
3. The cord set must have a rated current capacity of at least
10 A.
4. The attachment plug must be an earth-grounding type with
a NEMA 5-15P (15 A, 125 V) or NEMA 6-15P (15 A,
250 V) configuration.
Japan
1. All components of the cord set (cord, connector, and plug)
must bear a “T” mark and registration number in
accordance with the Japanese Dentori Law.
2. The minimum specifications for the flexible cord are:
❏
0.75 mm
2
conductors
❏
Type VCT or VCTF
❏
3-conductor
3. The cord set must have a minimum rated current capacity
of 7 A.
4. The attachment plug must be a two-pole, grounded type
with a Japanese Industrial Standard C8303 (15 A,
125 VAC) configuration.