3-25
Compaq ProLiant 1600 and ProLiant 1200 Servers Maintenance and Service Guide
POST Error Messages
Continued
Error Code
Audible
Beeps
L=Long
S=Short
Probable Source of
Problem
Action
1793-Drive
Array - Array
Accelerator
Battery
Depleted -
Data Lost
(Error message
1794 also
displays.)
None
This indicates that
while the system was
in use, power was
interrupted while
data was in the Array
Accelerator memory.
Array Accelerator
batteries failed. Data
in Array Accelerator
has been lost.
Power was not restored
within eight to ten days.
Perform orderly system
shutdowns to avoid
data remaining in the
Array Accelerator.
1794-Drive
Array - Array
Accelerator
Battery
Charge Low.
Array
Accelerator is
temporarily
disabled.
Array
Accelerator
will be re-
enabled when
battery
reaches full
charge.
None
This is a warning that
the battery charge is
below 75%. Posted
writes are disabled.
Replace the Array
Accelerator board if
batteries do not
recharge within 36
power-on hours.
1795-Drive
Array - Array
Accelerator
Configuration
Error.
Data does not
correspond to
this drive array.
Array
Accelerator is
temporarily
disabled.
None
This indicates that
while the system was
in use, power was
interrupted while
data was in the Array
Accelerator memory.
The data stored in the
Array Accelerator
does not correspond
to this drive array.
Match the Array
Accelerator to the
correct drive array, or
run the System
Configuration Utility to
clear the data in the
Array Accelerator.