3-46
Diagnostic Tools
SCSI Fixed Disk Drive Test Error Codes
The 6500 series of Diagnostic error codes identifies failures with SCSI fixed disk drives,
SCSI fixed disk drive controller boards, SCSI fixed disk drive cabling, and system board
functions. Corrective action may require replacement of the fixed disk drive cables, fixed
disk drive controller, fixed disk, or system board assembly. If your system uses a drive
array controller, see the section for Drive Array Advanced Diagnostics (DAAD).
Table 3-15
SCSI Fixed Disk Drive Test Error Codes
Error Code
Description
Recommended Action
6500-xx
6502-xx
6505-xx
6506-xx
6509-xx
6523-xx
6528-xx
SCSI Disk ID drive types test failed.
SCSI Disk Unconditional Format test
failed.
SCSI Disk Read Test Failed.
SCSI Disk SA/Media test failed.
SCSI Disk Erase tape test failed.
SCSI Disk Random Read test failed.
Media load/unload test failed.
The following steps apply to error
codes 6500-xx through 6599-xx:
1. Run the System Configuration
Utility and verify the drive type.
2. Replace the SCSI disk drive
signal and power cables and
retest.
3. Replace the SCSI controller and
retest.
4. Replace the SCSI disk drive and
retest.
5. Replace the system board and
retest.
SCSI/IDE CD-ROM Drive Test Error Codes
The 6600 series of Diagnostic error codes identifies failures with the CD-ROM cabling,
CD-ROM drive, adapter board, or system board assembly. Corrective action may require
replacement of the CD-ROM cabling, CD-ROM drive, adapter board, or system
board assembly.
Table 3-16
SCSI/IDE CD-ROM Drive Test Error Codes
Error Code
Description
Recommended Action