3-87
Compaq ProLiant 1600 and ProLiant 1200 Servers Maintenance and Service Guide
Critical Error Log
The Critical Error Log records memory errors, as well as catastrophic hardware and
software errors that cause the system to fail. This information helps you quickly identify
and correct the problem, thus minimizing downtime.
You can view the Critical Error Log through the Compaq Insight Manager. The Diagnostics
Utility either resolves the error or suggests corrective action in systems that do not support
event logs.
The Critical Error Log identifies and records all the following errors. Each error type is
briefly explained below.
Table 3-23
Critical Error Log Messages
Message
Description
Abnormal Program
Termination
The operating system has encountered an abnormal situation
that has caused a system failure.
ASR-2 detected by
ROM
An ASR-2 activity has been detected and logged by the
system ROM.
ASR-2 Test Event
The System Configuration Utility generated a test alert.
Automatic Server
Recovery Base
Memory Parity Error
The system detected a data error in base memory following a
reset due to the Automatic Server Recovery-2 (ASR-2) timer
expiration.
Automatic Server
Recovery Extended
Memory Parity Error
The system detected a data error in extended memory
following a reset due to the ASR-2 timer expiration.
Automatic Server
Recovery Memory
Parity Error
The system ROM was unable to allocate enough memory to
create a stack. Then, it was unable to put a message on the
screen or continue booting the server.
Automatic Server
Recovery Reset
Limit Reached
The maximum number of system resets due to ASR-2 timer
expiration has been reached, resulting in the loading of
Compaq Utilities.
Battery Failing
Low system battery warning. Replace battery within 7 days to
prevent loss of nonvolatile configuration memory. Failure of
the battery supporting the system’s nonvolatile RAM is
imminent.
Caution:
Temperature
Exceeded
The operating system has detected that the temperature of
the system has exceeded the caution level. Accompanying
data in the log notes if an auto-shutdown sequence has been
invoked by the operating system.
Diagnostic Error
An error was detected by the Diagnostics Utility. See the
specific error code in this chapter for a detailed explanation.