2-1
Compaq ProLiant 1600 and ProLiant 1200 Servers Maintenance and Service Guide
Chapter 2
Removal and Replacement
Procedures
This chapter provides subassembly/module-level removal and replacement procedures for
the ProLiant 1600 and ProLiant 1200 Servers. After completing all necessary removal and
replacement procedures, run the Diagnostics program to verify that all components
operate properly.
To service Compaq ProLiant 1600 and ProLiant 1200 Servers, you might need
the following:
■
Torx T-15 screwdriver
■
From the Compaq SmartStart and Support Software CD:
❏
System Configuration Utility software
❏
Drive Array Advanced Diagnostics software
❏
Diagnostics software
Electrostatic Discharge Information
A discharge of static electricity can damage static-sensitive devices or microcircuitry.
Proper packaging and grounding techniques are necessary precautions to prevent damage.
To prevent electrostatic damage, observe the following precautions:
■
Transport products in static-safe containers such as conductive tubes, bags,
or boxes.
■
Keep electrostatic-sensitive parts in their containers until they arrive at static-free
stations.
■
Cover work stations with approved static-dissipating material. Provide a wrist strap
connected to the work surface and properly grounded tools and equipment.
■
Keep work area free of non-conductive materials such as ordinary plastic assembly
aids and foam packing.
■
Make sure you are always properly grounded when touching a static-sensitive
component or assembly.
■
Avoid touching pins, leads, or circuitry.
■
Always place drives PCB assembly side down.
■
Use conductive field service tools.