3-66
Diagnostic Tools
DAAD Diagnostic Messages
Continued
Message
Description
Recommended Action
Logical Drive X
status = WRONG
DRIVE REPLACED
A physical drive in this logical
drive has failed. The incorrect
drive was replaced.
Replace the drive that was
incorrectly replaced. Then,
replace the original drive
that failed with a new drive.
Do not run the System
Configuration Utility to
reconfigure; you will lose
data on the drive.
Loose cable
detected - logical
drives may be
marked FAILED
until corrected
Controller unable to
communicate with one or
more physical drives, probably
because of a cabling
problem. Logical drives may
be in a FAILED state until the
condition is corrected,
preventing access to data on
the controller.
Check all controller and
drive cable connections.
Mirror data
miscompare
Data was found at
reinitialization in the posted
write memory; however, the
mirror data compare test
failed resulting in data being
marked as invalid. Data loss is
possible.
Replace the array
accelerator board.
Mirrored memory
location errors
Soft errors occurred when
attempting to read the same
data from both sides of the
mirrored memory. Data loss
will occur.
Replace the array
accelerator board.
No configuration
for Accelerator
Board
The array accelerator board
has not been configured.
If the array accelerator
board is present, run the
System Configuration Utility
to configure the board, if
desired.
Drive (bay) X has
loose cable
The array controller could not
communicate with this drive
at power-up. This drive has not
previously failed.
Check all cable
connections first. The cables
could be bad, loose, or
disconnected. Turn on the
system and attempt to
reconnect data/power
cable to the drive. If this
does not work, replace the