Diagnostic Tools
Table 3-20
DAAD Diagnostic Messages
Message
Description
Recommended Action
Accelerator board
not detected
Array controller did not
detect a configured array
accelerator board.
Install array accelerator
board on array controller. If
an array accelerator board
is installed, check for proper
seating on the array
controller board. You may
need to run the System
Configuration Utility and
disable the array
accelerator board to get
this message off the screen.
Accelerator error
log
List of the last 32 parity errors
on transfers to or from
memory on the array
accelerator board. Displays
starting memory address,
transfer count, and operation
(read and write).
If there are many parity
errors, you may need to
replace the array
accelerator board.
Accelerator parity
read errors: n
Number of times that read
memory parity errors were
detected during transfers
from memory on array
accelerator board.
If there are many parity
errors, you may need to
replace the array
accelerator board.
Accelerator parity
write errors: n
Number of times that write
memory parity errors were
detected during transfers to
memory on the array
accelerator board.
If there are many parity
errors, you may need to
replace the array
accelerator board.
Accelerator status:
Permanently
disabled
Array accelerator board has
been permanently disabled. It
will remain disabled until it is
reinitialized using the System
Configuration Utility.
Check the Disable Code
field. Run the System
Configuration Utility to
reinitialize the array
accelerator board.