3-18
Diagnostic Tools
POST Error Messages
Continued
Error Code
Audible
Beeps
L=Long
S=Short
Probable Source of
Problem
Action
1769-Slot x
Drive Array -
Drive(s)
disabled due
to failure
during
expand. Select
F1
to continue
with logical
drives
disabled.
Select
F2
to
accept data
loss and to re-
enable logical
drives.
None
SMART-2 Controller
error.
Data has been lost
while expanding the
array, therefore the
drives have been
temporarily disabled.
Press
F2
to accept the
data loss and re-enable
the logical drives.
Restore data from
backup.
1771-Primary
Disk Port
Address
Assignment
Conflict
None
Internal and external
hard drive controllers
are both assigned to
the primary address.
Run the System
Configuration Utility and
correct.
1772-
Secondary Disk
Port Address
Assignment
Conflict
None
Address Assignment
Conflict. Internal and
external hard drive
controllers are both
assigned to the
secondary address.
Run the System
Configuration Utility and
correct.
1773-Primary
Fixed Disk Port
Assignment
Conflict
None
Fixed disk drive error.
Run the System
Configuration Utility and
correct.