3-56
Diagnostic Tools
DAAD Diagnostic Messages
Continued
Message
Description
Recommended Action
Accelerator
status: Valid
data found at
reset
Valid data was found in posted
write memory at reinitialization.
Data will be flushed to disk.
Not an error or data loss
condition. No action needs
to be taken.
Accelerator
status: Warranty
alert
Catastrophic problem with
array accelerator board. Refer
to other messages on
Diagnostics screen for exact
meaning of this message.
Replace the array
accelerator board.
Adapter/NVRAM
ID mismatch
EISA nonvolatile RAM has an ID
for a different controller from
the one physically present in
the slot.
Run the System
Configuration Utility.
Battery pack X
below reference
voltage
Battery pack on the array
accelerator is below the
required voltage levels.
Allow enough time for
batteries to recharge (36
hours). If batteries have not
recharged after 36 hours,
replace the array
accelerator board.
Battery X not
fully charged
Battery is not fully charged.
If 75% of the batteries
present are fully charged,
the array accelerator is fully
operational. If more than
75% of the batteries are
not
fully charged, allow 36 hours
to recharge them.
Board not
attached
Array controller configured for
use with array accelerator
board, but one is not attached.
Attach array accelerator
board to array controller.
NVRAM
configuration
present,
controller not
detected
EISA nonvolatile RAM has a
configuration for an array
controller but there is no board
in this slot. Either a board has
been removed from the system
or a board has been placed in
the wrong slot.
Place the array controller in
the proper slot or run the
System Configuration Utility
to reconfigure nonvolatile
RAM to reflect the removal
or new position.
Compatibility
port problem
detected
Compatibility port configured
for this IDA controller. When
DAAD was verifying this
interface, a serious problem
was detected.
A hardware problem has
occurred; replace the IDA
controller.
Configuration
DAAD detected that
Run the latest version of