3-23
Compaq ProLiant 1600 and ProLiant 1200 Servers Maintenance and Service Guide
POST Error Messages
Continued
Error Code
Audible
Beeps
L=Long
S=Short
Probable Source of
Problem
Action
1789-Drive Not
Responding,
Physical Drive
Check cables
or replace
physical drive
X
.
Select "F1" to
continue -
drive array will
remain
disabled.
Select "F2" to
fail drive(s)
that are not
responding -
Interim
Recovery
Mode will be
enabled if
configured for
fault
tolerance.
None
Cable or hard drive
failure.
1. Check the cable
connections.
2. If cables are
connected, replace
the drive.
3. If you do not want to
replace the drives
now, press F2.
1790-Disk 0
Configuration
Error
None
Hard drive error or
wrong drive type.
Run the System
Configuration Utility and
Diagnostics and
correct.
1791-Disk 1
Error
None
Hard drive error or
wrong drive type.
Run the System
Configuration Utility and
Diagnostics and
correct.