Diagnostic Tools
DAAD Diagnostic Messages
Continued
Message
Description
Recommended Action
Drive (bay) X RIS
copy mismatch
The copies of the RIS on this
drive do not match.
This drive may need to be
replaced. Check for other
errors.
Drive (bay) X
upload code not
readable
An error occurred while DAAD
was trying to read the upload
code information from this
drive.
If there were multiple errors,
this drive may need to be
replaced.
Duplicate write
memory error
Data could not be written to
the array accelerator board in
duplicate due to the
detection of parity errors. This
is not a data loss situation.
Replace the array
accelerator board.
Error occurred
reading RIS copy
from drive (bay) X
An error occurred while DAAD
was trying to read the RIS from
this drive.
If there were multiple errors,
this drive may need to be
replaced.
FYI: Drive (bay) X is
non-Compaq
supplied
The installed drive was not
supplied by Compaq.
If problems exist with this
drive, replace it with a
Compaq drive.
Identify controller
data did not
match with
NVRAM
The identify controller data
from the array controller did
not match with the
information stored in
nonvolatile RAM. This could
occur if new, previously
configured drives have been
placed in a system that has
also been previously
configured. It could also
occur if the firmware on the
controller has been upgraded
and the System Configuration
Utility was not run.
Check the identify
controller data under the
Inspect Utility. If the
firmware version field is the
only thing different
between the controller and
nonvolatile RAM data, this is
not a problem. Otherwise
run the System
Configuration Utility.
Identify logical
drive data did not
match with
NVRAM
The identify unit data from the
array controller did not match
with the information stored in
nonvolatile RAM. This could
occur if new, previously
configured drives have been
placed in a system that has
also been previously
configured.
Run the System
Configuration Utility to
configure the controller and
nonvolatile RAM.
Insufficient
The adapter does not have
Operate the system without