3-12
Diagnostic Tools
POST Error Messages
Continued
Error Code
Audible
Beeps
L=Long
S=Short
Probable Source of
Problem
Action
1151-Com Port
1 Address
Assignment
Conflict
2S
Both external and
internal serial ports
are assigned to
COM1.
Run the System
Configuration Utility and
correct.
1152-Com Port
2, 3, or 4
Address
Assignment
Conflict
2S
Both external and
internal serial ports
are assigned to
COM2, COM3 or
COM4.
Run the System
Configuration Utility and
correct.
1600-Server
Manager/R
Failure
None
Server Manager/R
board failure. Error
code displays after
error message.
Run Diagnostics.
Replace failed
assembly as indicated.
1610-
Temperature
violation
detected.
Waiting for
system
to cool
2S
Ambient system
temperature too hot.
Check fan in system
environment.
1611-Fan
failure
detected
2S
Required fan not
installed or spinning.
Check fans.
1612-Primary
power supply
failure
2S
Primary power supply
has failed.
Replace power supply
as soon as possible.
1613-Low
System Battery
None
Real time clock
system battery is
running low on
power.
Run Diagnostics.
Replace failed
assembly as indicated.
1614-
Redundant fan
failure
detected
None
1701-SCSI
Controller
failure
None
A test on the Fast
SCSI-2 Controller
failed.
Run Diagnostics.
Replace failed
assembly as indicated.