TABLE 15 Link Status Mode (STAT) LED During Normal Operation (continued)
LED Color
Status of Hardware
Recommended Action
Flashing green
The link is up and traffic and packets are transmitted
or received.
None.
Steady amber
An error with incoming or outgoing packets.
None.
If you run the clear stats command, and the error
has been resolved, the port moves out of the steady
amber state.
Flashing amber
Possible reasons for flashing amber include:
•
UDLD is configured only on the local unit
but not on the peer unit.
•
LACP ports are in "Blocking" state.
•
A port is in "Error-Disabled" state due to
traffic-related issues.
Verify that your configuration is correct, and check
the traffic over the link.
Port Speed Status Mode (SPD) LED
Port speed status mode (SPD) displays the speed setting of each downlink and uplink port (including modules).
Refer to the following table to interpret the port speed status mode LED.
TABLE 16 Speed Status (SPD) LED During Normal Operation
LED Color
Status of Hardware
Recommended Action
Off
There is no valid link.
None.
Steady green
Highest speed.
None.
Flashing green
Second highest speed.
None.
Steady amber
Third highest speed.
None.
Flashing amber
Fourth highest speed.
None.
Alternating amber and green
Fifth highest speed.
None.
Member ID Status Mode (ID) LED
The member ID status mode (ID) LED displays the Stack ID.
With the switch configured in traditional stacking mode, this LED displays the stack member ID of the unit within the stack:
•
The member ID LED displays green.
•
Port LEDs are used to display the stack ID from 1 to 12 of each member within the stack.
Refer to the following table to interpret the member ID status mode LED.
TABLE 17 Member ID Status Mode (ID) LED During Normal Operation
LED Color
Status of Hardware
Recommended Action
Steady green
Port number is the same as the stack ID.
Or
Port number is the first digit of the PE ID.
None.
Monitoring the Device
Interpreting Port-Side LEDs
RUCKUS ICX 7550 Switch Hardware Installation Guide
82
Part Number: 53-1005648-04
Содержание RUCKUS ICX 7550
Страница 10: ...RUCKUS ICX 7550 Switch Hardware Installation Guide 10 Part Number 53 1005648 04 ...
Страница 54: ...RUCKUS ICX 7550 Switch Hardware Installation Guide 54 Part Number 53 1005648 04 ...
Страница 66: ...RUCKUS ICX 7550 Switch Hardware Installation Guide 66 Part Number 53 1005648 04 ...
Страница 76: ...RUCKUS ICX 7550 Switch Hardware Installation Guide 76 Part Number 53 1005648 04 ...
Страница 90: ...RUCKUS ICX 7550 Switch Hardware Installation Guide 90 Part Number 53 1005648 04 ...
Страница 102: ...RUCKUS ICX 7550 Switch Hardware Installation Guide 102 Part Number 53 1005648 04 ...
Страница 108: ...RUCKUS ICX 7550 Switch Hardware Installation Guide 108 Part Number 53 1005648 04 ...
Страница 114: ...RUCKUS ICX 7550 Switch Hardware Installation Guide 114 Part Number 53 1005648 04 ...
Страница 141: ... 2021 CommScope Inc All rights reserved 350 West Java Dr Sunnyvale CA 94089 USA https www commscope com ...