DANGER
Make sure the rack housing the device is adequately secured to prevent it from becoming unstable or falling over.
CAUTION
Do not use the port cover tabs to lift the module. They are not designed to support the weight of the module, which can fall and be
damaged.
CAUTION
To prevent damage to the chassis and components, never attempt to lift the chassis using the fan or power supply handles. These
handles were not designed to support the weight of the chassis.
Laser Precautions
DANGER
All fiber-optic interfaces use Class 1 lasers.
DANGER
Laser Radiation. Do Not View Directly with Optical Instruments. Class 1M Laser Products.
DANGER
Use only optical transceivers that are qualified by RUCKUS and comply with the FDA Class 1 radiation performance requirements
defined in 21 CFR Subchapter I, and with IEC 60825 and EN60825. Optical products that do not comply with these standards might emit
light that is hazardous to the eyes.
Facility Requirements
Before installing the device, be sure the facilities requirements are met.
TABLE 7 Facility Requirements
Type
Requirements
General
•
The site should be accessible for installing, cabling, and maintaining the devices.
•
Maintain the operating environment as specified in the Technical Specifications.
•
Allow at least 7.62 cm (3 in.) of space between the front and the back of the device and walls or other obstructions for
proper airflow.
•
Allow at least 7.62 cm (3 in.) of space at the front and back of the device for the twisted-pair, fiber-optic, and power cabling.
•
Allow the status LEDs to be clearly visible.
•
Allow for the unit to be connected to a separate grounded power outlet that provides 100 to 240 VAC, 50/60 Hz, within 2 m
(6.6 ft) of each device, and is powered from an independent circuit breaker. As with any equipment, a filter or surge
suppressor is recommended.
•
Allow for twisted-pair cables to be routed away from power lines, fluorescent lighting fixtures, and other sources of
electrical interference, such as radios and transmitters.
Electrical
•
Adequate supply circuit, line fusing, and wire size, as specified by the electrical rating on the switch nameplate
•
Circuit protected by a circuit breaker and grounded in accordance with local electrical codes
Tor complete power supply specifications, refer to
RUCKUS ICX 7550 Switch Technical Specifications
on page 115.
Preparing for the Installation
Facility Requirements
RUCKUS ICX 7550 Switch Hardware Installation Guide
Part Number: 53-1005648-04
23
Содержание RUCKUS ICX 7550
Страница 10: ...RUCKUS ICX 7550 Switch Hardware Installation Guide 10 Part Number 53 1005648 04 ...
Страница 54: ...RUCKUS ICX 7550 Switch Hardware Installation Guide 54 Part Number 53 1005648 04 ...
Страница 66: ...RUCKUS ICX 7550 Switch Hardware Installation Guide 66 Part Number 53 1005648 04 ...
Страница 76: ...RUCKUS ICX 7550 Switch Hardware Installation Guide 76 Part Number 53 1005648 04 ...
Страница 90: ...RUCKUS ICX 7550 Switch Hardware Installation Guide 90 Part Number 53 1005648 04 ...
Страница 102: ...RUCKUS ICX 7550 Switch Hardware Installation Guide 102 Part Number 53 1005648 04 ...
Страница 108: ...RUCKUS ICX 7550 Switch Hardware Installation Guide 108 Part Number 53 1005648 04 ...
Страница 114: ...RUCKUS ICX 7550 Switch Hardware Installation Guide 114 Part Number 53 1005648 04 ...
Страница 141: ... 2021 CommScope Inc All rights reserved 350 West Java Dr Sunnyvale CA 94089 USA https www commscope com ...