CommScope Era
™
Fiber Low Power Carrier Access Point Installation Guide
M0201ANC_uc
Page 6
© June 2019 CommScope, Inc.
Fiber CAP L Overview
Connectors and LED for the Fiber CAP L
and
identify the Fiber CAP L connectors and its LED; corresponding connectors are shown.
1
2
3
4
5
6
7
8
9
Figure 2.
CAP L Connectors and LED
Table 2.
Function of the CAP L Connectors and LED
REF #
Label
Description
Function
1, 4
ANT 3, ANT 4 Not available; connector is plugged.
2
ANT 1
4.3-10 RF connector
Connect to two separate external antennas or to two ports on a cross-polarized dual antenna
via 50
coaxial cable. Each connector supports two RF bands. The end of the 50
coaxial cable
that connects to an ANT connector can be either a push-pull or a threaded connector. The ANT
1 and ANT 2 ports ship with dust caps that can be discarded upon unit installation.
3
ANT 2
5
Power LED
(Unlabeled)
Power LED
See
"Powering on a Fiber CAP L” on page 62
.
6
Unlabeled
Proprietary 4-pin 36
to 60 Vdc Power
connector
Connects to a DC power supply, or to a Hybrid Fiber Junction Box; all four pins must be
terminated. The CAP L does not ship with any power cables preinstalled; you need to order the
power cable assembly that is appropriate for this installation:
• 7774061-xx: Cable Assembly, CAP L Local Power Jumper, 0.5m
• 7816237-xx: Cable Assembly, CAP L Local Power Jumper, 3m
7
2
Optical Port 2
If the CAP L is functioning as a Primary CAP L in a cascade, Optical Port 2 connects to Optical Port
1 of the Secondary CAP L via the Optical OCTIS Kit (PN 7770612), which ships with the unit, to
provide the main signal interface. Optical transport occurs over Single Mode Fiber (SMF) or
Multi Mode Fiber (MMF). Port 2 ships with factory-installed EMI/weatherproof plug and must
remain plugged if not in use. Graphic shows the OCTIS connector in blue.
8
1
Optical Port 1
Connects to a Classic CAN or TEN (possibly through a local Hybrid Fiber Junction Box) and
provides the main signal interface; if Secondary CAP L in a cascade, Optical Port 1 connects to
Optical Port 2 of the Primary CAP L. Optical transport occurs over Single Mode Fiber (SMF) or
Multi Mode Fiber (MMF). Uses the Optical OCTIS Kit (PN 7770612), which ships with the unit.
Port 1 ships with a dust cap that can be discarded upon unit installation. Graphic shows the
OCTIS connector in blue.
9
A
RJ45 Auxiliary port
Connects to external Ethernet devices such as WiFi and IP cameras. Cabling is via the
appropriate CAT cable for the protocol; this model supports a 1000 BASE-T and 802.3at Class 4
Power over Cat6A Ethernet connection. Maximum attached cable length is 3 meters (9.8 feet).
For information on the Auxiliary port in cascades, see
"Cascade Rules for Fiber CAP Ls” on
. Port A ships with factory-installed EMI/weatherproof plug and must remain plugged if
not in use. (Graphic shows the port populated with an OCTIS Ethernet connector PN 7760652
which must be ordered separately—see