Abbreviations, signals, terms,…
78
OOL:
Out Of Label - see paper break / paper break check
Operator Panel:
used to controlled the labeling unit, used to set the system parameter like
Labeling speed, label predispensing and label sensor.
Paper break:
the paper break is used to controlled break the paper moving (paper path
from unwinder to dispensing edge)
The (optional) paper break control is able to sense a paper break situation
(OOL = Out Of Label) = control unit (see also optional OOL) – integrated in
the paper break
Position:
Position of the label on the product
Predispensing:
Predispensing of the label on the dispensing edge. Section (mm) of the l
label on the dispensing edge overlapping the dispensing edge.
Rewinder:
Passive rewinder: the rewinder will be driven by the main stepper motor
(belt driven) – a friction clutch is used to control the movement.
Right version:
paper will be drown (dispensed) from left to right (view to the front of the
labeling unit)
Start frequency:
max. allowed stepper motor frequency (start from stop to start frequency –
without ramp up function)
Step distance:
is the distance the paper is moving forward while moving the stepper motor
one step forward – also called step resolution
SLA
S
pring
L
oaded
Applicator
– the dispensing edge will be pushed down
toward the product (spring force)
Stop accuracy:
accuracy of the label position on the dispensing edge
Stop frequency:
max. allowed stepper motor frequency (stop motor from stop frequency to
motor stop – without ramp down function)
TUO:
Traction Unit Open – the pressure roller is NOT pressing on to the traction
roller (lift up position of the pressure roller)
Traction unit:
part of the labeler – stepper motor moving the paper (backing paper) over
the dispensing edge
Good sensor:
we can offer/recommend different good sensors - depending on the
constitution of the product (good):
ask for Sick WT150-P460, Sick WL150-P430 or others – see also GSC