Conne buildup [electronic]
55
8 Conne buildup [electronic]
8.1 Mainboard
8.1.1 Safety
Basic
WARNING!
Take care while connecting sensors/actors to the
Collamat C4300/C7300 inputs and outputs!
Inappropriate handling on the Collamat C4300/C7300
electronic parts can destroy delicate components.
Wiring jobs and repairs should be carried out by thepersons
designated (see 3. Safety –
3.3.1 Requirements).
Organize and take care of your working environment – is
there enough room to fulfill your job?
Always look out for a clean and organized mounting area. A
messy place is always a place of danger (cause of accident).
Open collector- und power-connections have to be current
limited – according to the specified max. values (see
Technical Manual).
8.1.2 Connections „main-connecting terminals“
Terminal
Function (signal name)
Terminal number
!GSC
NPN-good scanner (GND, signal, 12V)
X7-1, X7-2, X7-3
!LSC
Label sensor receiver (GND, signal, 12V)
X7-4, X7-5, X8-1
TCY
Label sensor sender (signal, 12V)
X8-2, X8-3
!RDY
Ready input (GND, signal)
X8-4, X8-5
!FEED
Feed output (internal signal)
X9-1
!IFD, IFD
Isolated Feed output (!IFD, IFD) - Open collector
X9-2, X9-3
12V + GND
Power supply for sensors, …. (12V, GND)
X9-4, X9-5
!ERR, ERR
Error output (!ERR, ERR) - Open collector
X10-1, X10-2