Start-up and operation
50
7.4 Operation
Operator panel
The operator panel of the Collamat C4300/C7300 is used to adjust the
labeling parameters. Use the potentiometers to adjust the speed,
predispensing and label sensor, the main switch for power on/off and the
feed key to eject a (test) label.
3 Potentiometer, 1 main power switch and a FEED-key.
7.4.1 Adjusting the labeler on the operator panel
The Collamat C4300/C7300 will be controlled/adjusted via operator panel.
Depending on the material and shape of product and label – the good scanner
and/or the label scanner has to be adjusted after a product or label change. The
meaning of the different adjusting parameter will be explained in a separate
chapter.
Important adjustments:
POWER ON/OFF
main power switch of the labeler
FEED:
FEED-key
SPEED:
Dispensing speed (m/min)
LABEL PREDISPENSING: Label predispensing (mm)
LABEL SCANNER:
Label sensor (sender current)
The following part describes the most important parameters (short form):
POWER ON/OFF
Switch on/off main
power
The „POWER ON/OFF“ switch will be used to switch the main power (AC) to
the labeler. The red lamp in the switch will illuminate if the switch is in it’s ON
state (main power present and fuse F1 ok).
FEED - key
Eject a label
This key is wired parallel to the good scanner input. Use this key function to
simulate a good scanner trigger signal (!GSC-input) or check the potentiometer
adjustments.