Technical specifications
25
3.3 Technical data
Connected load
Description
Value
Unit
Supply voltage (AC)
115 / 230 VAC
Phases
1~ Ph
Frequency
60 / 50 Hz
Maximum energy input
138/198 VA
Internal mains fuse
5.0/2.5 AT
External mains fuse
10 AT
Protection type (digit 1 – 3)
(explanation see below)
standard 402
IP
Compressed air
(optional maintenance unit)
6 bar
Compressed air quality class as
per ISO 8573-1
Class 5
Oil-free
and dry
Caution: Only well trained labor are allowed to do the
rewiring of the main power connections!
* C4300 / C7300
Explanation - IP protection 1
st
. digit:
Protection against touching and
against intrusion of foreign particle
Description
Value Unit
Protection against mass. foreign particle >1mm
4 IP
Explanation - IP protection 2nd. digit:
Protection against intrusion of water
Description
Value Unit
No particular protection
0 IP
Explanation - IP protection 3rd. digit:
Mechanical protection
Description
Value Unit
Power of impact: 0.375 Joule (Test: 250g – 15cm)
2 IP
Operating conditions
Description
Value
Unit
Temperature range
+5 ... +40 °C
Temperature fluctuation, max.
10 °C/h
Storage temperature
-10 ... +60 °C
Relative humidity, max.
non-condensing
15 - 95 %
Environment
avoid direct sunlight,
dampness and dust