After this simple procedure, the entire motor and effects assembly is able to be remo-
ved and any complex procedures carried out.
Replacing the fuse
Locate the fuse which protects the lamp and electronic circuitryin the base of the
CF
1200 Spot
.
Using a multimeter, test the condition of the fuse, replacing it with one of equivalent
type if necessary.
Periodic cleaning
Lenses and reflectors
Even a fine layer of dust can reduce the luminous output substantially. Regularly
clean all lenses and the reflector using a soft cotton cloth, dampened with a speciali-
sed lens cleaning solution.
Fans and air passages
The fans and air passages must be cleaned approximatley every 6 weeks; the period
for this periodic cleaning will depend, of course, upon the conditions in which the
projector is operating. Suitable instruments for performing this type of maintenance
are a brush and a common vacuum cleaner or an air compressor.
Periodic maintenance
Lamp
The lamp should be replaced if there is any observable damage or deformation due
to heat. This will avoid the danger of the lamp exploding.
Mechanicals
Periodically check all mechanical devices for wear and tear; gears, guides, belts, etc.,
replacing them if necessary.
Periodically check the lubrication of all components, particularly the parts subject to
high temperatures. If necessary, lubricate with suitable lubricant (
coemar
cod.
MV
6173/1
)
Electical components
Check all electrical components for correct earthing and proper attachment of all
connectors, refastening if necessary.