7. Mains connection
cabling
The mains cable provided is thermally resistant, complying to the most recent inter-
national standards. It meets or exceeds the VDE and IEC norms, IEC 331, IEC 332
3C, CEI 20 35.
NB: In the case of cable replacement, similar cable, with comparable thermal resi-
stant qualities must be used exclusivelly (cable 3x1,5 ø external 10 mm, rated
300/500V, tested to 2KV, operating temperature -40° +180°,
coemar
cod.
CV5309).
mains connection
CF 1200 Spot
can operate at voltages from 208V-230V-240V at 50 or 60Hz (ope-
rating voltage and frequency can be selected as described in section 5 of this
manual).
Prior to connecting the unit to your mains supply, ensure that the model in your pos-
session correctly matches the mains supply available to you.
For connection purposes, ensure your plug is of a suitable rating: 9,5 amps.
Locate the mains cable which exits the base of the unit and connect as shown
below:
marrone - brown
blu - blue
giallo/verde - yellow/green
marrone - brown
blu - blue
giallo/verde - yellow/green
massa
gr
ound
neutr
o
neutral
fase
phase
alimentazione
main
marrone - brown
blu - blue
giallo/verde - yellow/green