4. Lamp: Installation
CF 1200 Spot
utilises a 1200 W Philips MSR 1200 SA lamp.
and replacement
with a GY 22.lamp base
The lamp is available from your authorised
coemar
sales agents:
coemar cod.
105090/1
wattage
1200 w
luminous flux
96.000 lm
colour temperature
6500° K
base
GY 22
approximate life
500 hours
The fixture’s internal temperature can reach 250° C after 5 minutes, with a maximum
peak of 350° C; ensure that the bulb is cold before attempting removal. The fixture
should be allowed to stand and cool for 10 minutes prior to its removal.
MSR/SA lamps are part of the mercury vapour family of discharge lamps and must be
handled with great care. The lamp operates at high pressure, and the slight risk of
explosion of the lamp exists if operated over its recommended life of 500 hours.
We recommend, therefore, that the lamp be replaced within the manufacturer’s spe-
cified lamp life.
lamp installation
1) With the use of a 3mm Allen Key, loosen the two bolts (
A
) which fix the lamp
assembly to the body of the projector.
2) Remove the lamp assembly (
B
).
3) Locate the lampholder (
C
)
Attention
Disconnect mains power prior to inspecting the unit internally.