GR740-UM-DS, Nov 2017, Version 1.7
99
www.cobham.com/gaisler
GR740
9.4.13 Error Handling / Injection configuration
Table 81.
0x4C - L2CEINJCFG - L2C injection configuration register
(only available in revision 1)
9.4.14
Table 82.
0x80-FC - L2CMTRR - L2C Memory type range register
Memory type range registers
31
11 10
9
8
7
0
RESERVED
E
D
I
T
E
R
I
M
D
RES
0
0
0
0
0
r
rw rw rw
r
31: 11
RESERVED
10
(EDI) - Enable invalidation off cache line with un-correctable data error.
When set to 1 and a un-correctable data error is detected, the cache line will be invalidated (remov-
ing the error form the cache).
.This field is only available in silicon revision 1.
9
(TER) - Disable error response on un-correctable TAG error detection.
When set to 0 the access detecting a un-correctable TAG error would generate a AMBA error
response. When set to 1 this access would not generate an error response.
This field is only available in silicon revision 1.
8
(IMD) - Disable index match only after un-correctable TAG error.
When set to 1 the TAG and INDEX are matched against the error address register after a detected un-
correctable TAG error. When set to 0 only the INDEX are matched against the error address register.
This field is only available in silicon revision 1
7: 0
RESERVED
31
18 17 16 15
2
1
0
ADDR
ACC
MASK
WP AC
0
0
0
0
0
rw
rw
rw
rw rw
31: 18
Address field (ADDR) - to be compared to the cache address [31:18]
17: 16
Access field (ACC) - 00: uncached, 01: write-through
15: 2
Address mask (MASK) - Only bits set to 1 will be used during address comparison
1
Write-protection (WP) - 0: disabled, 1: enabled
0
Access control field (AC) -. 0: disabled, 1: enabled