GR740-UM-DS, Nov 2017, Version 1.7
258
www.cobham.com/gaisler
GR740
Table 320.
0x84 - RTC - GR1553B RT Config register
31
16
15
14
13
12
7
6
5
1
0
RTKEY
SYS
SYDS
BRS
RESERVED
RTEIS
RTADDR
RTEN
0
1
1
1
0
0
0b11111
0
w
rw
rw
rw
r
r
rw
rw
31 : 16
Safety code (RTKEY) - Must be written as 0x1553 when changing the RT address, otherwise the address
field is unaffected by the write. When reading the register, this field reads 0x0000.
If extra safety keys are enabled (see Hardware Config Register), the lower half of the key is used to also pro-
tect the other fields in this register.
15
Sync signal enable (SYS) - Set to ‘1’ to pulse the rtsync output when a synchronize mode code (without
data) has been received
14
Sync with data signal enable (SYDS) - Set to ‘1’ to pulse the rtsync output when a synchronize with data
word mode code has been received
13
Bus reset signal enable (BRS) - Set to ‘1’ to pulse the busreset output when a reset remote terminal mode
code has been received.
12: 7
RESERVED
6
(RTEIS) - Reads ‘1’ if current address was set through external inputs.
After setting the address from software this field is set to ‘0’
5 : 1
RT Address (RTADDR) - This RT:s address (0-30)
0
RT Enable (RTEN) - Set to ‘1’ to enable listening for requests
Table 321.
0x88 - RTBS - GR1553B RT Bus status register
31
9
8
7
5
4
3
2
1
0
RESERVED
TFDE
RESERVED
SREQ
BUSY
SSF
DBCA
TFLG
0
0
0
0
0
0
0
0
r
rw
r
rw
rw
rw
rw
rw
31: 9
RESERVED
8
Set Terminal flag automatically on DMA and descriptor table errors (TFDE)
7: 5
RESERVED
4 : 0
These bits will be sent in the RT:s status responses over the 1553 bus.
4
Service request (SREQ)
3
Busy bit (BUSY)
Note: If the busy bit is set, the RT will respond with only the status word and the transfer “fails”
2
Subsystem Flag (SSF)
1
Dynamic Bus Control Acceptance (DBCA)
Note: This bit is only sent in response to the Dynamic Bus Control mode code
0
Terminal Flag (TFLG)
The BC can mask this flag using the “inhibit terminal flag” mode command, if legal
Table 322.
0x8C - RTSW - GR1553B RT Status words register
31
16
15
0
BIT WORD (BITW)
VECTOR WORD (VECW)
0x0000
0x0000
rw
rw
31 : 16
BIT Word (BITW) - Transmitted in response to the “Transmit BIT Word” mode command, if legal
15 : 0
Vector word (VECW) - Transmitted in response to the “Transmit vector word” mode command, if legal.
Table 323.
0x90 - RTSY - GR1553B RT Sync register
31
16
15
0
SYNC TIME (SYTM)
SYNC DATA (SYD)
0x0000
0x0000
r
r
31 : 16
Sync Data (SYD) - The value of the RT timer at the last sync or sync with data word mode command, if legal.
15 : 0
Sync Time (SYTM) - The data received with the last synchronize with data word mode command, if legal