GR740-UM-DS, Nov 2017, Version 1.7
280
www.cobham.com/gaisler
GR740
* Read-only or read-write depends on the register according to the previous description
Note that the TxAHBErr interrupt is generated in such way that the corresponding read and write
pointers are valid for failure analysis. The interrupt generation is independent of the Can-
CONF.ABORT field setting.
Note that the RxAHBErr interrupt is generated in such way that the corresponding read and write
pointers are valid for failure analysis. The interrupt generation is independent of the Can-
CONF.ABORT field setting.
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
16
TxLoss - Message arbitration lost during transmission (could be caused by communications error, as
indicated by other interrupts as well)
15
RxMiss - Message filtered away during reception
14
TxErrCntr - Transmission error counter incremented
13
RxErrCntr - Reception error counter incremented
12
TxSync - Synchronization message transmitted
11
RxSync - Synchronization message received
10
Tx - Successful transmission of message
9
Rx - Successful reception of message
8
TxEmpty - Successful transmission of all messages in buffer
7
RxFull - Successful reception of all messages possible to store in buffer
6
TxIRQ - Successful transmission of a predefined number of messages
5
RxIRQ - Successful reception of a predefined number of messages
4
TxAHBErr - AHB error during transmission
3
RxAHBErr - AHB error during reception
2
OR - Over-run during reception
1
OFF - Bus-off condition
0
PASS - Error-passive condition
Table 359.
Interrupt Registers