![Cloos NexT 452 AC Скачать руководство пользователя страница 73](http://html1.mh-extra.com/html/cloos/next-452-ac/next-452-ac_operating-instructions-manual_2625802073.webp)
73
Transfer of PAK files
In this menu item you can select the following functions:
Designation
Function
Allowed (default)
Unknown users are allowed to log in at the weld-
ing power source.
Information of unknown users are saved at the
welding power source.
Not allowed
Only users who are listed in the configuration of
the welding power source are allowed to log in.
Welding process enable
In this menu item you can select the following functions:
Designation
Function
Always
The welding power source always activates the
welding process, even if no user is logged in.
After login (default)
The welding power source only activates the
welding process after successful login.
Job range enable
In this menu item you can select the following functions:
Designation
Function
All
The user can call and use all jobs (1 … 999) which
are stored in the welding power source.
Allowed jobs
(default)
The user can only call and use the allowed jobs.
It is possible to specify defined parameter limits (setting ranges) within
a job for the "Automatic" and "Programmer" operating levels, see section
"6.4 MAIN - Programming - Setting ranges" on page 49.
Auto log off of configurator
Designation
Function
Off (default)
The user with the "Configurator" operating level is
not logged off automatically.
… min.
The user with the "Configurator" operating level
is logged off automatically after a preset time
(1min … 30min).
If no input is made via the operating module during the preset time
period, the access state is reset to the preset "Operating level after switch
on".
Input of password via keyboard
In this menu item you can select the following functions:
Designation
Function
Allowed (default)
The manual input of a 6-digit code number at the
welding power source is allowed.
Not allowed
The user can only log in to the welding power
source with a PAK.
INFO!
INFO!
Содержание NexT 452 AC
Страница 4: ......
Страница 11: ...11 Block 1 Operational Safety...
Страница 27: ...27 Block 2 Basic information Qineo NexT...
Страница 110: ...110 Job mode...
Страница 148: ...148...
Страница 149: ...149 Block 4 Additional information...
Страница 164: ...164 SD module...
Страница 184: ...184 General commissioning 8 3 2 QWD P5 QWD M5 The illustrations may differ from the original INFO 4 3 2 1...
Страница 191: ...191 Block 6a Error messages...
Страница 207: ...207 Block 6b General maintenance instructions...
Страница 208: ...208 1 Maintenance and Care 1 7 4 5 2 3 8 10 Optional external cooling unit 10 9 Optional lifting eyes 3 11...
Страница 212: ...212...
Страница 213: ...213 Block 7 Automation...
Страница 232: ...232...
Страница 233: ...233...
Страница 234: ...www qineo de...