203
No. Error message on the display
Possible cause
Remedy
582 BMP - 64KB exceeded
Overall size of logos stored in
the operating module exceeded.
(MasterPlus)
Delete image file for logo in the
operating module.
583 SD Error
Limit value exceeded/not
reached triggering a collective
fault SD.
Check SD logbook
600 Emergency stop
Master controller has triggered a
signal.
601 Safety stop
Master controller has triggered a
signal.
610 Error 24V outputs
24V for peripheral interface (X70)
and reserve output 3 (A9-X16)
Service
611 Error 24V outputs
24V collective fault (A9-X16) and
Arc_on signal (X70)
Service
613 Error 24V outputs
24V RPU (X30) and VBC (A9-X23)
Service
614 Error 24V outputs
24V signal enable PCU (A8-X9)
and 24V RC (A9-X24)
Service
615 Error 24V outputs
24V robot interface (A9-X21)
Service
620 Internal USB stick not found
Data carrier missing/faulty
Check data carrier
Insert data carrier again
Service
621
Internal USB stick is write-
protected
Data carrier faulty
Check data carrier
Insert data carrier again
Service
622 Internal USB stick is full
Not enough free storage space.
Replace data carrier
Service
650 Cooling module failed
Connection to the module
interrupted during operation.
Switch machine Off and On
Check plug and connections
Service
651
Software version cooling
module out-of-date
Software update required
Software update
Service
652
Cooling module - fan excess
temperature
Overheating of the module,
Device dirty
Let the machine cool down
Check filter mats and change if
necessary
Clean machine with dry air
Clean heat sink
Check sensors (service)
653
Cooling module - pump
excess temperature
Overheating of the module
Device dirty
Service
654
Undervoltage cooling
module !
Input voltage outside the
permissible value range of
360 V...440 V
Check input voltage
Replace cooling module
Service
Содержание NexT 452 AC
Страница 4: ......
Страница 11: ...11 Block 1 Operational Safety...
Страница 27: ...27 Block 2 Basic information Qineo NexT...
Страница 110: ...110 Job mode...
Страница 148: ...148...
Страница 149: ...149 Block 4 Additional information...
Страница 164: ...164 SD module...
Страница 184: ...184 General commissioning 8 3 2 QWD P5 QWD M5 The illustrations may differ from the original INFO 4 3 2 1...
Страница 191: ...191 Block 6a Error messages...
Страница 207: ...207 Block 6b General maintenance instructions...
Страница 208: ...208 1 Maintenance and Care 1 7 4 5 2 3 8 10 Optional external cooling unit 10 9 Optional lifting eyes 3 11...
Страница 212: ...212...
Страница 213: ...213 Block 7 Automation...
Страница 232: ...232...
Страница 233: ...233...
Страница 234: ...www qineo de...