![Cloos NexT 452 AC Скачать руководство пользователя страница 182](http://html1.mh-extra.com/html/cloos/next-452-ac/next-452-ac_operating-instructions-manual_2625802182.webp)
182
General commissioning
8.2 Disassembly reducing insert
The CLOOS wire drive units' gas connector is provided with a mechanical
reducing insert having a bore of Ø0.6mm. This insert adapts the gas flow
to the litre scale of the pressure reducer on the gas cylinder.
In the case that a company is working with a central gas supply (inlet pres-
sure 6 … 8bar), the welding torch will not be provided with a sufficient gas
quantity. Therefore, the reducing insert must be removed; see the QWD-M
example in the following diagram.
Designation
Function
Screw
M4
Disassembly of the reducing
insert
2
1