![Cloos NexT 452 AC Скачать руководство пользователя страница 194](http://html1.mh-extra.com/html/cloos/next-452-ac/next-452-ac_operating-instructions-manual_2625802194.webp)
194
No. Error message on the display
Possible cause
Remedy
21 Low water flow rate
Optional machine equipment.
Water flow rate lower than limit
value (lines too long).
Option water monitoring, check water
flow rate
Check limit values
Refill coolant, if required.
Ventilate pump.
Check cooling circuit
Service
22 High water temperature
Optional machine equipment.
Water temperature higher than
limit value.
Option water monitoring, check water
temperature
Check limit values
Refill coolant, if required.
Ventilate pump
Service
23 Arc failure "Process phase"
Arc interruption during the
welding process. During welding,
the arc parameters fall below
a certain level for more than 1
second.
Check process settings
Check wire drive unit
Check gas
Deactivate process monitoring
Service
24 Arc failure "Ignition phase"
If the arc does not burn within 5
seconds after the start signal.
Check welding wire / wire drive unit
Service
39
Robot software version out-
of-date
Software update required.
Software update
Service
41
Software version remote
control out-of-date
Software update required.
Software update
Service
44
Software version VBC
DeviceNet out-of-date
Software update required.
Software update
Service
45 VBC DeviceNet module failed
Communication between control
and DeviceNet module faulty.
Switch machine Off and On
Check plug and connections (CAN BUS)
Service
46 VBC DeviceNet bus failed
Communication between
DeviceNet Master and module
(Slave) faulty.
Switch machine Off and On
Check plug and connections
(DeviceNet)
Service
47
Software version VBC
ProfiNet out-of-date
Software update required.
Switch machine Off and On
Check plug and connections
Service
48 VBC ProfiNet module failed
Communication between control
and ProfiNet module faulty.
Switch machine Off and On
Check plug and connections (CAN BUS)
Service
49 VBC ProfiNet bus failed
Communication between control
and ProfiNet module faulty.
Switch machine Off and On
Check plug and connections (ProfiNet)
Service
50 VBC Profibus failed
Communication between control
and ProfiNet module faulty.
Switch machine Off and On
Check plug and connections (ProfiNet)
Service
51 QWD1 failed
CAN connection interrupted.
Switch machine Off and On
Check plug and connections
Service
Содержание NexT 452 AC
Страница 4: ......
Страница 11: ...11 Block 1 Operational Safety...
Страница 27: ...27 Block 2 Basic information Qineo NexT...
Страница 110: ...110 Job mode...
Страница 148: ...148...
Страница 149: ...149 Block 4 Additional information...
Страница 164: ...164 SD module...
Страница 184: ...184 General commissioning 8 3 2 QWD P5 QWD M5 The illustrations may differ from the original INFO 4 3 2 1...
Страница 191: ...191 Block 6a Error messages...
Страница 207: ...207 Block 6b General maintenance instructions...
Страница 208: ...208 1 Maintenance and Care 1 7 4 5 2 3 8 10 Optional external cooling unit 10 9 Optional lifting eyes 3 11...
Страница 212: ...212...
Страница 213: ...213 Block 7 Automation...
Страница 232: ...232...
Страница 233: ...233...
Страница 234: ...www qineo de...