![Cloos NexT 452 AC Скачать руководство пользователя страница 199](http://html1.mh-extra.com/html/cloos/next-452-ac/next-452-ac_operating-instructions-manual_2625802199.webp)
199
No. Error message on the display
Possible cause
Remedy
265
CDD4 Desired rotation speed
not reached
Preset rotation speed not
reached. Encoder signals faulty
motor movement.
Check motor movement
Check CDD
Check wire feed distance
Check CDD cable connections
Check encoder
Fuse 42V supply faulty
Power supply board
Service
266
System - External RAM
memory error
RAM chip on control board
missing or faulty.
Service
267 Invalid job number
Invalid job number requested.
Repeat operation
Service
268 Job not available
A non-existent job has been
called up.
Check available jobs
Service
269 Timeout during data transfer Error in data transfer.
Check data carrier
Check plug and connections
Service
270
Checksum error during data
transfer
Error in data transfer.
Check data carrier
Check plug and connections
Service
271 Wrong file version
File version cannot be processed
by current software.
Check software versions when
transferring data from one machine to
the other
Software update may be required
Service
272 Error in file format
Faulty file
Use correct file format
Service
274 QWD1- Overcurrent
Overload results in increased
current load of the drive unit.
Check wire feed distance
Service
275 QWD2- Overcurrent
Overload results in increased
current load of the drive unit.
Check wire feed distance
Service
276 QWD3- Overcurrent
Overload results in increased
current load of the drive unit.
Check wire feed distance
Service
277 QWD4- Overcurrent
Overload results in increased
current load of the drive unit.
Check wire feed distance
Service
278 CDD1- Overcurrent
Overload results in increased
current load of the drive unit.
Check wire feed distance
Service
279 CDD2- Overcurrent
Overload results in increased
current load of the drive unit.
Check wire feed distance
Service
280 CDD3- Overcurrent
Overload results in increased
current load of the drive unit.
Check wire feed distance
Service
281 CDD4- Overcurrent
Overload results in increased
current load of the drive unit.
Check wire feed distance
Service
282
Tandem software version
Slave out-of-date
Software version not compatible.
Synchronise software
Service
Содержание NexT 452 AC
Страница 4: ......
Страница 11: ...11 Block 1 Operational Safety...
Страница 27: ...27 Block 2 Basic information Qineo NexT...
Страница 110: ...110 Job mode...
Страница 148: ...148...
Страница 149: ...149 Block 4 Additional information...
Страница 164: ...164 SD module...
Страница 184: ...184 General commissioning 8 3 2 QWD P5 QWD M5 The illustrations may differ from the original INFO 4 3 2 1...
Страница 191: ...191 Block 6a Error messages...
Страница 207: ...207 Block 6b General maintenance instructions...
Страница 208: ...208 1 Maintenance and Care 1 7 4 5 2 3 8 10 Optional external cooling unit 10 9 Optional lifting eyes 3 11...
Страница 212: ...212...
Страница 213: ...213 Block 7 Automation...
Страница 232: ...232...
Страница 233: ...233...
Страница 234: ...www qineo de...