Sound levels
Standard mode
SIZE
Sound power level
Sound
pressure
level
Sound
power
level
Octave band (Hz)
63
125
250
500
1000 2000 4000 8000
dB(A)
dB(A)
16.2
69
72
73
76
77
73
65
55
65
80
20.2
70
73
74
77
77
74
67
57
66
81
24.2
70
72
75
78
79
75
69
59
67
82
30.2
67
79
73
76
79
74
67
58
66
82
35.2
74
75
75
77
81
75
68
60
68
83
40.2
77
77
75
78
81
76
70
62
69
84
Silenced mode
SIZE
Sound power level
Sound
pressure
level
Sound
power
level
Octave band (Hz)
63
125
250
500
1000 2000 4000 8000
dB(A)
dB(A)
16.2
74
72
68
70
72
73
65
57
62
77
20.2
74
72
68
70
72
73
65
57
62
77
24.2
74
72
68
70
72
73
65
57
62
77
30.2
63
79
72
74
74
70
63
54
62
78
35.2
63
79
72
74
74
70
63
54
62
78
40.2
63
79
72
74
74
70
63
54
62
78
Super silenced mode
SIZE
Sound power level
Sound
pressure
level
Sound
power
level
Octave band (Hz)
63
125
250
500
1000 2000 4000 8000
dB(A)
dB(A)
16.2
52
71
63
69
68
67
58
49
58
73
20.2
52
71
63
69
68
67
58
49
58
73
24.2
52
71
63
69
68
67
58
49
58
73
30.2
64
71
67
72
71
68
63
53
60
75
35.2
64
71
67
72
71
68
63
53
60
75
40.2
64
71
67
72
71
68
63
53
60
75
At maximum conditions data
Sound levels refer to units with nominal test
conditions.
The sound pressure level refers to a distance
of 1 meter from the outer surface of the unit
operating in open field.
Noise levels are determined using the tensiome-
tric method (UNI EN ISO 9614-2)
Data referred to the following conditions in
cooling:
- internal exchanger water = 12/7°C
- ambient temperature = 35°C
Sound levels refer to units with nominal test
conditions.
The sound pressure level refers to a distance
of 1 meter from the outer surface of the unit
operating in open field.
Noise levels are determined using the tensiome-
tric method (UNI EN ISO 9614-2)
Data referred to the following conditions in
cooling:
- internal exchanger water = 12/7°C
- ambient temperature = 35°C
Silenced mode can be set from the user interfa-
ce terminal.
Sound levels refer to units with nominal test
conditions.
The sound pressure level refers to a distance
of 1 meter from the outer surface of the unit
operating in open field.
Noise levels are determined using the tensiome-
tric method (UNI EN ISO 9614-2)
Data referred to the following conditions in
cooling:
- internal exchanger water = 12/7°C
- ambient temperature = 35°C
Super Silenced mode can be set from the user
interface terminal.
SIZE
Sound power level
Sound
pressure
level
Sound
power
level
Octave band (Hz)
63
125
250
500
1000 2000 4000 8000
dB(A)
dB(A)
16.2
70
72
75
78
79
75
69
59
67
82
20.2
70
72
75
78
79
75
69
59
67
82
24.2
70
72
75
78
79
75
69
59
67
82
30.2
77
77
75
78
81
76
70
62
69
84
35.2
77
77
75
78
81
76
70
62
69
84
40.2
77
77
75
78
81
76
70
62
69
84
Sound levels refer to units with nominal test
conditions.
The sound pressure level refers to a distance
of 1 meter from the outer surface of the unit
operating in open field.
Noise levels are determined using the tensiome-
tric method (UNI EN ISO 9614-2).
81
Содержание WSAT-YES FC
Страница 1: ...M0NC00002 00 12 20 WSAT YSi...
Страница 2: ...Cool Antifreeze heater Signals Remote On Off Rapid guide CN33 CN24...
Страница 20: ...1 Piping inlet outlet side 2 Electrical panel side 3 Anchoring bolts Size 16 2 24 2 Size 30 2 40 2 1 2 3...
Страница 26: ...Storage tank Option Vent Drain On Off Inverter pump Option...
Страница 34: ...UNITA IN CONFIGURAZIONE MODULARE...
Страница 85: ...85...
Страница 86: ...Via Camp Lonc 25 Z I Villapaiera 32032 Feltre BL Italy Tel 39 0439 3131 Fax 39 0439 313300 info clivet it...