General technical data
Performance
SIZE
16.2
20.2
24.2
30.2
35.2
40.2
RADIANT PANELS
Cooling
Cooling capacity
kW 1/4
64,0
72,0
80,0
92,0
101
113
EER
2
4,02
3,76
3,07
4,16
3,78
3,37
Water flow-rate
l/s
1
3,14
3,54
3,93
4,50
4,89
5,56
User side exchanger pressure drops
kPa 1
38
47
57
52
61
78
TERMINAL UNIT
Cooling
Cooling capacity
kW 3
43
54
65
76
87
98
EER
2
3,30
3,14
2,76
3,25
3,07
2,79
SEER
5
4,97
4,81
4,65
5,37
5,15
4,95
ηs,c
%
6
196
189
183
212
203
195
Water flow-rate
l/s 5
2,14
2,51
3,06
3,60
4,21
4,58
User side exchanger pressure drops
kPa 3
18
25
36
34
46
54
The Product is compliant with the ErP (Energy Related Products) European Directive. It includes the Commission delegated Regulation (EU) No 811/2013 (rated heat output ≤ 70 kW at
specified reference conditions) and the Commission delegated Regulation (EU) No 813/2013 (rated heat output ≤ 400 kW at specified reference conditions).
1. Entering/leaving water temperature user side 23/18 °C, Entering external exchanger air temperature 35 °C.
2. EER (EN 14511:2018) cooling performance coefficient. Ratio between delivered coolimg capacitu and power input in compliance with EN 14511:2018.
3. User side entering/leaving water temperature 12/7 °C, external exchanger entering air 35 °C.
4. Data referred to unit operation with inverter frequency optimized for this application.
5. Data calculated according to the EN 14825:2016 Regulation.
6. The seasonal space cooling efficiency ηs, c expressed in%.
Construction
SIZE
16.2
20.2
24.2
30.2
35.2
40.2
Compressor
Compressor type
ROTARY INVERTER
SCROLL INVERTER
Refrigerant
R32
N° compressor
Nr
2
2
2
2
2
2
Oil charge
l
4,6
4,6
4,6
4,2
4,2
4,2
Refrigerant charge
Kg
4,5
4,5
4,5
7,5
7,5
7,5
N° circuits
Nr
1
1
1
1
1
1
User side exchanger
Type of internal exchanger
1
BHPE
Water content
l
5,7
5,7
5,7
7,8
7,8
7,8
External Section Fans
Fans type
BRUSHLESS DC MOTOR
N° fans
Nr
2
2
2
3
3
3
Standard air-flow
l/s
6944
6944
6944
10417
10417
10417
Installed unit power
kW
0,8
0,8
0,8
0,9
0,9
0,9
Water circuit
Maximum water side pressure
MPa
1
1
1
1
1
1
Minimum circuit water volume in
cooling
2
l
150
150
150
200
200
200
Total internal water volume
l
6
6
6
6
6
6
Power supply
Standard power supply
400/3/50+N
400/3/50+N
400/3/50+N
400/3/50+N
400/3/50+N
400/3/50+N
7. BPHE = plate exchanger
8. Entering/leaving water temperature user side 15/10 °C, external exchanger entering air 25°C (U.R. = 85%) - Minimum water volume that does not consider the volume of water
inside the unit.
80
Содержание WSAT-YES FC
Страница 1: ...M0NC00002 00 12 20 WSAT YSi...
Страница 2: ...Cool Antifreeze heater Signals Remote On Off Rapid guide CN33 CN24...
Страница 20: ...1 Piping inlet outlet side 2 Electrical panel side 3 Anchoring bolts Size 16 2 24 2 Size 30 2 40 2 1 2 3...
Страница 26: ...Storage tank Option Vent Drain On Off Inverter pump Option...
Страница 34: ...UNITA IN CONFIGURAZIONE MODULARE...
Страница 85: ...85...
Страница 86: ...Via Camp Lonc 25 Z I Villapaiera 32032 Feltre BL Italy Tel 39 0439 3131 Fax 39 0439 313300 info clivet it...