Replacing the Lifting Eye Bolts
After the cabinet is securely mounted, seal the roof by replacing the lifting eyebolts with button-head Allen bolts from the
installation kit.
Note:
The four bolts on the cabinet roof secure the roof assembly to the cabinet. When replacing the eyebolts, remove and
replace each bolt in sequence. Do not remove all bolts at the same time.
CAUTION!
Replace the eyebolts one at a time to ensure that the roof is securely attached to the cabinet at all
times.
To replace the lifting eyebolts
Step 1:
Using a screwdriver, unscrew and remove a lifting eyebolt from the top of the cabinet.
Using the Clearfield-supplied telco hex key, install a button-head Allen bolt into the vacant bolt hole.
Repeat Steps 1 and 2 to replace each additional lifting eyebolt on the cabinet roof, one at a time.
Step 2: