16
Select a location:
There are several considerations when selecting a location for your new furnace:
(1) Do not obstruct shop personnel or equipment
(2) Find a location where the warm air will be evenly distributed.
(3) The installation must meet the clearance to combustible material requirements (Figure 11)
(4) The location must be safely accessible for maintenance and service
(5) The installation must comply with all local codes and regulations
(6) Keep the stack / chimney system simple. A complicated stack with multiple elbows and
long horizontal runs will reduce the natural draft of the unit which can damage critical
burner components.
Figure 11: Clearances to Combustible Materials
Minimum Distances from Combustible Materials
WARNING:
Carefully follow all installation instructions for safe and efficient operation.
FURNACE INSTALLATION
UNIT HEATER
UNIT HEATER
CENTRAL FURNACE
(with side warm air outlet)
(with bottom warm air outlet)
Front (burner)
60"
Front (burner)
60"
Front (burner)
60"
Back (blower)
2"
Back (blower)
2"
Back (blower)
2"
Side with air outlet
60"
Side
12"
Side
12"
Side with no air outlet
12"
Top of furnace
18"
Top of furnace
18"
Top of furnace
18"
Bottom
60"
Bottom
18"
Bottom
18"
Single wall chimney pieces
18"
Ductwork
(within 3ft of furnace)
6"
Single wall chimney pieces
18"
Single wall chimney pieces
18"
CE70165
BACK 2"
TOP 18"
SIDE WITHOUT
AIR OUTLET 12"
BOTTOM 60"
STACK 18"
AIR OUTLET
SIDE 60"
FRONT 60"
(BURNER)
Содержание CE-140
Страница 50: ...50 NOZZLE ADAPTER HEATER BLOCK ASSEMBLY 2 3 19 5 7 8 15 9 17 14 18 16 13 1 4 6 10 11 12 ...
Страница 52: ...52 MANIFOLD BLOCK ASSEMBLY 8 6 2 1 4 17 3 9 5 7 12 13 14 15 16 18 19 11 10 ...
Страница 58: ...58 3 4 6 1 2 5 CE 140 180 BLOWER ...
Страница 62: ...62 2 3 4 5 6 1 CE 250 BLOWER ...
Страница 66: ...66 CE 330 BLOWER 12 8 7 4 13 1 2 3 5 6 9 10 11 ...
Страница 70: ...70 CE 440 BLOWER 12 8 7 4 13 1 2 3 5 6 9 10 11 ...
Страница 72: ...72 METERING PUMP ASSEMBLY WITH A2RA 7720 PUMP HEAD 3 1 2 4 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 22 23 5 21 ...