Control System (Battery Model)
29
Service Manual – Clarke CA30 20B and 17E
4. Remove the 2 coil wires
(K)
from the brush relay
(M)
.
5. Remove the two power wires
(L)
from the brush
relay.
6. Remove the 4 screws
(Q)
that
secure the control board
(P)
to
the enclosure
(A)
, and remove
the control board.
7. Remove the 2 screws
(N)
that
secure the brush relay
(M)
to the
enclosure, and remove the relay.
M
K
L
M
A
N
P
Q