− 54 −
No.
Problems
Causes
Actions
Teaching pendant is valid. Check teaching pendant.
Wiring is wrong.
Reconfirm Section 6 of this Instruction Manual.
There is breaking of wire.
Check pinching and breaking of wires, connectors,
and terminals.
Overload error has
occurred.
Reconfirm transfer load and speed.
Power supply capacity is
insufficient.
Check if power supply meets necessary voltage
and current.
Servomotor is OFF at
emergency stop.
Check parameter settings based on teaching
pendant instruction manual.
Load that exceeds
retaining force is acting.
Confirm retaining force in Section 7.6 and make
sure external force that exceeds retaining force is
not acting.
8
Positioning
completion output
does not go OFF.
Positioning completion
output width is too wide
relative to moving
distance
Check parameter settings based on teaching
pendant instruction manual.
9
PUSH/Press-in
movements cannot
be performed.
Product is not set to
PUSH/press-in
movements.
Confirm teaching pendant instruction manual
before operating.
10
Loss of
synchronization
occurs.
Product is overloaded or
over speeding.
Make sure work piece mass and operating speed
meet specified values.
11
Abnormal stroke
length occurs.
Product has broken down
or is damaged.
Repair is necessary. Please contact CKD after
confirming Section 10.1.
12
Product has no
speed. (It is
extremely slow.)
Product is set to
PUSH/press-in
movements instead of
general transfer movement.
Check setting data with teaching pendant.
13 Overshoot occurs.
Transfer load is large and
deceleration is big.
Make sure work piece mass and operating speed
meet specified values. Decrease acceleration
value.
14
Target tact is not
reached.
Acceleration and speed
settings are wrong.
Check setting data with teaching pendant.
Communication cable is
broken.
Check cable connector condition. Replace if there
is breaking.
There is no corresponding
answer input.
Repair is necessary. Please contact CKD after
confirming Section 10.1.
If these actions do not resolve the problems, please contact CKD.
6
Product does not
move with PLC.
15
Product does not
communicate with
teaching pendant.
7
Work piece moves
due to its own
weight at
emergency stop.